In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is

(A) 0.2 Ω (B) 0.3 Ω (C) 0.4 Ω (D) 0.5 Ω
in Electrical Machine by

1 Answer

0 like 0 dislike

In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is 0.3 Ω