A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is

(A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω
in Electrical Measurements and Instrumentation by

1 Answer

0 like 0 dislike

A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

by

Related questions

0 answers
asked Aug 13 by anonymous | 24 views
2 answers

9,139 questions

7,898 answers

145 comments

3,245 users