A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is

(A) 2.5 W (B) 5 W

(C) 32.5 W (D) 35 W

1 Answer

0 votes
by

A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is 35 W

Related questions

1 answer 37 views

An induction type energy meter is found to run fast. Correction for this error can be made by  (A) Over-load compensation. (B) Voltage compensation. (C) Moving the brake magnet away from the centre of the disc. (D) Moving the brake magnet towards the centre of the disc.

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 29 views

The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

asked Apr 25, 2018 in Instrumentation and control by Shimroz123
1 answer 14 views

A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is (A) 300 W (B) 150 W (C) 45 W (D) 20 W

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
1 answer 13 views

Draw a block diagram of electronic energy meter. Write function of each block.

asked Sep 6, 2018 by Shimroz123
1 answer 17 views

Draw a neat sketch of 1-ph induction type energy meter and write operating principle of it. 

asked Sep 6, 2018 by Shimroz123
1 answer 22 views

Phantom loading for testing of energy meter is used (A) to isolate the current and potential circuits (B) to increase power loss during testing (C) for meters having low current ratings (D) to test meters having a large current rating for which loads may not be available

asked Apr 28, 2018 in Electronics Engineering by Shimroz123
1 answer 29 views

Explain the “mitigation of power theft” and “faulty meter replacement” for energy conservation techniques to reduce commercial losses. 

asked Sep 22, 2018 in Energy Conservation And Audit by Shimroz123
1 answer 10 views

State the function and shape of following parts used in induction type energy meter: i) Series magnet ii) Shunt magnet iii) Al disc iv) Brake magnet

asked Sep 6, 2018 by Shimroz123
2 answers 3 views

State the meaning of creeping error in 1 phase energy meter.

asked Sep 6, 2018 by Shimroz123
1 answer 36 views

A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

asked May 3, 2018 in Electrical Machine by Shimroz123
1 answer 10 views

Draw and describe working of electronic energy meter.

asked Sep 6, 2018 by Shimroz123
1 answer 30 views

With neat diagram explain calibration of energy meter by direct loading method.

asked Sep 6, 2018 by Shimroz123
1 answer 9 views

Write any two advantages of digital energy meter.

asked Sep 5, 2018 by Shimroz123
1 answer 15 views

List any four errors in induction type energy meter. Give method of compensation for each.

asked Sep 5, 2018 by Shimroz123
1 answer 8 views

What is meant by energy meter constant?

asked Sep 6, 2018 by Shimroz123
1 answer 11 views

Why energy meter is integrating type measuring instrument?

asked Sep 5, 2018 by Shimroz123
0 answers 25 views

A d.c. ampere-hour meter is rated at 5A, 250 V. The declared constant is 5 A sec/revolution. The constant in revolution/kwh will be (a) 2880 (b) 2680 (c) 2480 (d) 2280

asked May 25, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 90 views

 When The dc converter in figure shown has a resistance load of R = 10 Ω and the input voltage is Vs 220 V the converter switch remains on, its voltage drop is Vo -2 V. The chopping frequency is fI K sW Vs If the duty cycle is 50%, determine: (a) the average output voltage V (b) the RMS output voltage Vo (c) the converter efficiency (d) the effective input resistance of the converter

asked Apr 26 by Hussein
1 answer 15 views

A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

asked May 8, 2018 in Electrical Machine by Shimroz123
1 answer 18 views

A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

asked Apr 28, 2018 in Power Electronic Controlled Drives by Shimroz123
1 answer 12 views

The Eb/V ratio of a d.c. motor is an indication of its?

asked Mar 26, 2018 in DC motor by Shimroz123
1 answer 40 views

What is the stored energy when 200 V is applied across a 7 μF capacitor? A) 1400 Joules B) 0.7 Joules C) 0.14 Joules D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
0 answers 21 views

A dc shunt motor runs at 500 r.p.m at 220 V. A resistance of 4.5 Ω is added in series with the armature for speed control. The armature resistance is 0.5 ohms. The current to stall the motor will be (1) 44 A (2) 50 A (3) 44.4 A (4) 60 A  

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
0 answers 19 views

The full scale range of PMMC voltmeter is 100 V and its sensitivity is 1000 Ω/V. If the meter reads 50 V, the current through the voltmeter is (A) 0.05 mA (B) 0.5 mA (C) 5 mA (D) 50 mA 

asked Jun 4, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 16 views

A cumulatively compounded d.c. generator is supplying 20 A at 200 V. If the series field winding is short circuited, the terminal voltage will (a) remain unaltered (b) rise to 220 V (c) shoot up to a very high value (d) become less than 200 V 

asked May 25, 2018 in DC generator by Shimroz123
1 answer 15 views

In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :

asked Apr 29, 2018 in Electrical Machine by Shimroz123
1 answer 39 views

The normal value of the armature resistance of a d.c. motor is?

asked Mar 26, 2018 in DC motor by Shimroz123
1 answer 18 views

As there is no back e.m.f. at the instant of starting a D.C. motor, in order to prevent a heavy current from flowing though the armature circuit?

asked Mar 20, 2018 in Electrical Machine by Shimroz123
1 answer 47 views

The power factor of a D.C. circuit is always?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 26 views

A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

asked Apr 29, 2018 in Electrical Measurements and Instrumentation by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,450 questions

7,047 answers

132 comments

3,084 users

...