For 11kV line the inductance per km per phase will be of the order of: 

(A) 1 H (B) 0.1 H (C) 1 mH (D) 0.1 mH

Your answer

Thanks for your contribution. Feel free to answer this question. Please avoid short answer. Your answer is most welcome. Be genuine.

Upload image or document:

Your name to display (optional):
Privacy: Your email address will only be used for sending these notifications.
Anti-spam verification:
Are you a robot ? (Y = Yes / N = No)
To avoid this verification in future, please log in or register.

1 Answer

0 votes
by

For 11kV line the inductance per km per phase will be of the order of: 1 mH

Related questions

1 answer 18 views

For 11 kV line the capacitance per km per phase will be of the order of:  (A) 1 Farad (B) 0.1 Farad (C) 0.01 Farad (D) 0.01 microF

asked May 8, 2018 in Electric Power Transmission by Shimroz123
1 answer 41 views

The inductance of single phase two wire power transmission line per km gets doubled when the  (a) Distance between wires is doubled  (b) Distance between the wires is increased four fold  (c) Distance between the wires is increased as square of the original distance  (d) Radius of the wire is doubled

asked May 13, 2018 in Electric Power Transmission by Shimroz123
2 answers 50 views

Write the relation between phase and line current, phase and line voltage for Star connection.

asked Aug 11, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 38 views

For a 500 Hz frequency excitation, a 50 km long power line will be modeled as

asked Apr 29, 2018 in Power system by Shimroz123
1 answer 32 views

What is the difference between line and phase current?

asked Mar 10, 2018 in High voltage engineering by Quiz
1 answer 50 views

What is the difference between line and phase voltage?

asked Mar 10, 2018 in High voltage engineering by Quiz
4 answers 173 views

What is the voltage in 3 phase line?

asked Dec 22, 2017 in Fundamentals of electrical power systems by Quiz
0 answers 50 views

What is line voltage and phase voltage? Draw balanced three phase star connected system. Show all the voltages and currents.

asked Aug 11, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 115 views

In a transmission line if booster transformers are to be used, preferred location will be  (A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

asked May 8, 2018 in Electric Power Transmission by Shimroz123
1 answer 43 views

For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is

asked Apr 30, 2018 in Electrical Engineering by Shimroz123
1 answer 20 views

A 800 kV transmission line is having per phase line inductance of 1.1 mH/km and per phase line capacitance of 11.68 nF/km. Ignoring the length of the line, its ideal power transfer capability in MW is (A) 1204 MW (B) 1504 MW (C) 2085 MW (D) 2606 MW

asked May 25, 2018 in Power system by Shimroz123
1 answer 101 views

A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of

asked May 3, 2018 in Electric Power Transmission by Shimroz123
0 answers 17 views

A three phase 50 Hz, 400 kV transmission line is 300 km long. The line inductance is 0.97 mH/km per phase and capacitance is 0.0115 mF/km per phase. Assume a loss less line. Determine the line wavelength (a line phase constant).  (A) 1250 km (B) 6578 km (C) 4990 km (D) 2445 km 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 46 views

For a balanced three phase star connected load for which line voltage is 230V and per phase resistance and reactance is 6 Ohm and 8 Ohm respectively. Calculate: 1) phase voltage 2) line current 3) power factor 4) total power absorbed

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 31 views

Stability of a transmission line can be increased by

asked May 8, 2018 in Electric Power Transmission by Shimroz123
1 answer 123 views

A 50Ω transmission line is terminated in an impedance of 20-j50. What will be the reflection coefficient? A) 0.69 B) 1.69 C) 6.9 D) 16.9 

asked Jun 18, 2018 in Electrical Engineering by Shimroz123
1 answer 22 views

A transmission line of 200 km has a certain A, B, C and D parameters. If the length is reduced to 60 km

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
1 answer 18 views

The self inductance of a coil can be measured using (A) Wien’s Bridge (B) Schering Bridge (C) Anderson’s Bridge (D) Wheatstone Bridge

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 24 views

The inductance of a coil can be increased by?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 3 views

Describe with working of LCR meter for measurement of inductance. 

asked Sep 6, 2018 by Shimroz123
1 answer 14 views

In an R-C phase shift oscillator, the minimum no. of R-C networks to be connected in cascade will be -

asked May 8, 2018 in Electrical Engineering by Shimroz123
1 answer 21 views

What will be the phase angle between two alternating waves of equal frequency, when one wave attains maximum value the other is at zero value ?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 27 views

The bridge method commonly used for finding mutual inductance is (A) Heaviside Campbell bridge (B) Schering bridge (C) De Sauty bridge (D) Wien bridge

asked Apr 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 82 views

The power consumed in a circuit element will be least when the phase difference between the current and voltage is?

asked Mar 24, 2018 in Electrical Engineering by Shimroz123
1 answer 51 views

If 3000 kW power is to be transmitted over a distance of 30 km, the desirable transmission voltage will be.  (A) 11 kV (B) 33 kV (C) 66 kV (D) 132 kV

asked May 8, 2018 in Electric Power Transmission by Shimroz123
2 answers 95 views

The sending end and receiving end voltages of a three-phase transmission line are 10 kV/ph and 9.5 kV/ph, respectively. If the resistance drop is 150 V/ph and receiving end power factor is 0.8, the sending end power factor is (A) 0.745 lagging (B) 0.775 lagging (C) 0.8 lagging (D) 0.85 lagging

asked Apr 28, 2018 in Power system by Shimroz123
1 answer 24 views

lt the length, number of turns and area of a coil are  doubled, the inductance of the coil

asked Apr 26, 2018 in Electrical Engineering by Shimroz123
1 answer 41 views

The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is_______Vs.

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

When both the inductance and resistance of a coil are doubled the value of?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 166 views

What is the reciprocal of inductance?

asked Jan 7, 2018 in Electrical Engineering by ProblemSolver
1 answer 24 views
0 answers 52 views

A 220 kV, 3 phase transmission line is 60 km long. The resistance is 0.15 ohm / km and the inductance is 1.4 mH / km. Use the short line model to find the power at the sending end when the line is supplying a three phase load of 300 MVA at 0.8 pf lagging at 220 kV.  (A) 5.58MW (B) 80MW (C) 85.58MW (D) 74.42 MW 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

The unit circle of the Nyquist plot transforms into unity or 0 dB line of the amplitude plot of the Bode diagram for

asked Apr 26, 2018 in Control System by Shimroz123
1 answer 44 views

In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

asked Mar 18, 2018 in Alternator by Shimroz123
0 answers 46 views

The following circuit has following parameters. Ac=Ag=9cm2 g=30cm N=500 Meur=70000 Find the Inductance of the coil

asked 4 days ago in Electrical Engineering by Sam9045
1 answer 13 views

Inductance of coil?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 18 views

Inductance of a coil Varies?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 19 views

Inductance affects the direct current flow?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 22 views

The surge impedance for over head line is taken as  (1) 10-20 ohms (2) 50-60 ohms (3) 100-200 ohms (4) 1000-2000 ohms

asked May 1, 2018 in Switchgear And Protection by Shimroz123
1 answer 7 views

What is inductance?

asked Jul 4 by Shimroz123
1 answer 28 views

Self inductance formula

asked Jun 11 by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,530 questions

7,129 answers

135 comments

3,090 users

...