24 views
in Switchgear And Protection by
Light triggering is mainly used in

1 Answer

0 votes
by

Light triggering is mainly used in High voltage direct current transmission

Related questions

1 answer 16 views

The hum in a transformer is mainly attributed to?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 12 views

Which triggering is the most reliable?

asked May 8, 2018 in Power Electronics by Shimroz123
1 answer 39 views

RC triggering is preferred over resistance triggering because (A) it provides triggering at a precise instant (B) it gives a longer duration gate pulse (C) it enables triggering at a larger value of firing angle (D) it protects the SCR against high dv/dt

asked Apr 28, 2018 in Power Electronic Controlled Drives by Shimroz123
1 answer 38 views

Describe triggering circuit for TRIAC using DIAC.

asked Feb 16, 2018 in Unit 5 by Quiz
1 answer 19 views

A 100-watt light bulb turned on for 8 hours uses :  (A) 800 Wh (B) 0.8 kWh (C) 8 kWh (D) None of the above

asked May 8, 2018 in Electrical Engineering by Shimroz123
1 answer 12 views

The iron alloy, ALNICO is mainly used to make ________ A) Temporary magnets B) Permanent magnets C) Transmission lines D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
1 answer 13 views

Auto reclosing is used in case of

asked May 3, 2018 in Switchgear And Protection by Shimroz123
1 answer 23 views

The material used in liquid fuses is  (1) SF6 (3) carbon tetra chloride (2) distilled water (4) transformer oil

asked Apr 30, 2018 in Switchgear And Protection by Shimroz123
1 answer 39 views

Regulating-transformers are used in power systems for control of

asked Apr 26, 2018 in Switchgear And Protection by Shimroz123
1 answer 53 views

A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

asked May 8, 2018 in Switchgear And Protection by Shimroz123
1 answer 26 views

Earthing switch is used for?  (A) Measuring of safety voltage (B) Protection of equipment from ground faults (C) Discharging residual energies (D) All of the above 

asked May 8, 2018 in Switchgear And Protection by Shimroz123
1 answer 366 views

A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

asked May 1, 2018 in Switchgear And Protection by Shimroz123
1 answer 22 views

ln a minimum oil circuit breaker the oil is used

asked Apr 26, 2018 in Switchgear And Protection by Shimroz123
1 answer 21 views

IDMT relays are used to protect the transformer against :  (A) Internal short -circuits (B) Open circuits (C) External short circuits (D) Oil leakage

asked Apr 30, 2018 in Switchgear And Protection by Shimroz123
1 answer 13 views

Series reactors are used to

asked Apr 26, 2018 in Switchgear And Protection by Shimroz123
1 answer 45 views

Surge absorbers are used for protection against

asked Apr 26, 2018 in Switchgear And Protection by Shimroz123
1 answer 134 views

Shunt compensation in an EHV line is used to (A) Improve stability. (B) Improve the voltage profile. (C) Reduce the fault level. (D) Substitute for synchronous phase modifier.

asked May 8, 2018 in Power system by Shimroz123
2 answers 38 views

The IC chips, used in computers, is made of  (1) Iron oxide (2) Silicon (3) Graphite (4) Silica

asked May 1, 2018 in Computer Engineering by Shimroz123
1 answer 17 views

A differentiator is not usually used in control system, because it : - (A) reduces damping  (B) increases error  (C) reduces gain margin  (D) increases input noise

asked Apr 30, 2018 in Control System by Shimroz123
1 answer 16 views

A dummy strain gage is used in a quarter bridge strain gage circuit to :  (A) compensate for changes in temperature and lead wire resistance  (B) produce more output voltage from the bridge  (C) increase the sensitivity of the bridge  (D) compensate lead wire resistance only

asked Apr 29, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 15 views

The range of frequencies used in induction heating is :  (A) 0-25 Hz  (C) less than 200 Hz  (B) 50 to 100 Hz  (D) more than 1 kHz

asked Apr 29, 2018 in Utilization of electrical energy by Shimroz123
1 answer 58 views

An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be  (1) unaffected (2) decreased (3) increased (4) either decreased or increased depending on the direction of the DC field

asked Apr 29, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 28 views

The storage battery generally used in electric power stations is  (1) zinc carbon battery (2) lead acid battery (3) nickel cadmium battery (4) lithium -ion battery

asked Apr 29, 2018 in Power system by Shimroz123
1 answer 27 views

Series capacitive compensation in EHV transmission line is used to

asked Apr 29, 2018 in Power system by Shimroz123
1 answer 13 views

The effect of a finite gain of an operational amplifier used in an integrator is that (A) it would not integrate (B) the slope of the output will vary with time (C) the final value of the output voltage will reduce (D) there will be instability in the circuit

asked Apr 26, 2018 in Electronics Engineering by Shimroz123
1 answer 29 views

Silicon steel is used in electrical machines because it has?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
0 answers 19 views

What type of biasing is used in CE amplifier?

asked Mar 22, 2018 in Transistor Biasing by Quiz
1 answer 10 views
1 answer 17 views

The damping winding in synchronous motor is generally used to?

asked Mar 18, 2018 in Synchronous machine by Shimroz123
1 answer 25 views

Which type of motor is used in lift?

asked Mar 11, 2018 in Utilization of electrical energy by Quiz
0 answers 13 views

Which motor is used in traction system?

asked Mar 11, 2018 in Utilization of electrical energy by Quiz
1 answer 32 views

State functions of ; i) Cable box ii) Guard wire iii) Shackle insulator iv) Stay wire used in service connection

asked Sep 20, 2018 in Industry Electrical Systems-I by Shimroz123
1 answer 10 views

Give the classification of the errors used in measuring instrument & state the reason for their occurrence.

asked Sep 6, 2018 by Shimroz123
1 answer 11 views

Name the material used for :- (i) Moving coil (ii) Permanent magnet in PMMC instrument.

asked Sep 6, 2018 by Shimroz123
1 answer 2 views

State the use of shunt and series resistance used in extension of meter.

asked Sep 6, 2018 by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units
...