Can you help by answering this question?

Load flow study of a power system is mainly carried out for

21 views
in DC machine by
For continuously running rolling mills with intermittent loading, the most suitable DC drive is 

 (a) DC series motor (b) DC shunt motor (c) DC differentially compound motor (d) DC cumulatively compound motor 

1 Answer

0 votes
by

For continuously running rolling mills with intermittent loading, the most suitable DC drive is DC cumulatively compound motor 

Related questions

1 answer 22 views

Suggest the energy conservation techniques in following cases : (i) Motor is running with 70% loaded condition. (ii) Motor is continuously loaded at 50%. (iii) Motor runs with 30% loaded condition but sometimes rises to 50% loading condition. (iv) Motor runs continuously under no-load condition.

asked Oct 3, 2018 in Energy Conservation And Audit by Shimroz123
0 answers 18 views

The large d.c. motors used in steel rolling mills are always provided with compensating . windings for (a) opposing the armature mmf (b) maintaining the voltage (c) maintaining the speed (d) none of these

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
1 answer 9 views

Which type of motor is most suitable for computerprinter drive?  A) Reluctance motor B) Hysteresis motor C) Shaded pole motor D) Stepper motor

asked May 17, 2018 in Electrical Machine by Shimroz123
0 answers 18 views

The dc motor used for intermittent high torque loads is  (1) dc series motor (2) dc shunt motor (3) differential compound motor (4) cumulative compound motor

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
1 answer 72 views

D.C. motor is to drive a load which has certain minimum value for most of the time and some peak value for short duration. We will select the?

asked Mar 20, 2018 in DC motor by Shimroz123
1 answer 12 views

The most suitable refrigerant for a commercial ice plant is : (A) brine (B) NH3 (C) Freon (D) air

asked Jun 15, 2018 in Mechanical Engineering by Shimroz123
1 answer 27 views

For using regenerative breaking, the most suitable motor is :  (A) DC series motor  (B) Slip ring induction motor  (C) Squirrel cage induction motor  (D) Synchronous motor

asked Apr 29, 2018 in Electrical Machine by Shimroz123
0 answers 26 views

The most suitable material for transformer core is  (1) hot rolled grain oriented steel (2) cold rolled grain oriented steel (3) aluminium (4) copper

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
1 answer 22 views

The most suitable motor for low power applications is a/an:  (A) dc series motor (B) dc shunt motor (C) ac two-phase induction motor (D) ac series motor

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
1 answer 15 views

Which scheduling policy is most suitable for a time-shared operating system?  A) Shortest job first B) Round robin C) First come first serve D) Elevator

asked Apr 11, 2018 in Computer Engineering by Shimroz123
1 answer 23 views

The terminal characteristics of a dc generator suitable for electric welders is (A) separately excited generator (B) shunt generator (C) series generator (D) differentially compounded generator

asked Apr 28, 2018 in Electrical Engineering by Shimroz123
1 answer 72 views

Give broad classification of maintenance with meaning of each type. State the factors on which ideal maintenance of electric rolling stock is judged. Give any two means to improve any one factor of these.

asked Sep 2, 2018 by Shimroz123
1 answer 14 views

In a DC machine, which of the following statements is true ?  (A) Compensating winding is used for neutralizing armature reaction while interpole winding is used for producing residual flux (B) Compensating winding is used for neutralizing armature reaction while interpole winding is used for improving ... winding is used for neutralizing armature reaction (D) Compensation winding is used for improving commutation while interpole winding is used for producing residual flux

asked May 17, 2018 in DC machine by Shimroz123
1 answer 47 views

Explain DC coupled drive circuit with unipolar output.

asked Feb 19, 2018 in Unit 5 by Quiz
0 answers 14 views

Which is the most efficient Belt Drive?  A) V Belt B) Flat Belt C) Toothed Belt D) All of the above

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
0 answers 9 views

One of the most powerful tool for dealing with unbalanced polyphase circuit is the method of symmetrical components introduced by the scientist (a) Gauss (b) Volta (c) Newton (d) C.L. Fortescue

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
0 answers 21 views

To generate 1 MHz signal, the most suitable circuit is (a) Wein bridge oscillator (b) Phase shift oscillator (c) Colpitts oscillator (d) None of these  

asked May 25, 2018 in Electronics Engineering by Shimroz123
1 answer 17 views

A 50 kW dc shunt is loaded to draw rated armature current at any given speed. When driven  (i) at half the rated speed by armature voltage control and (ii) at 1.5 times the rated speed by field control, the respective output powers delivered by the motor are approximately. (A) 25 kW in (i) and 75 kW in (ii) (B) 25 kW in (i) and 50 kW in (ii) (C) 50 kW in (i) and 75 kW in (ii) (D) 50 kW in (i) and 50 kW in (ii)

asked May 17, 2018 in DC machine by Shimroz123
1 answer 38 views

What are the slot wedges in a DC machine made of?   (a) Mild steel (b) Silicon steel (c) Fibre (d) Cast iron

asked May 13, 2018 in DC machine by Shimroz123
1 answer 39 views

A d.c. shunt motor is found suitable to drive fans because they require?

asked Mar 26, 2018 in DC motor by Shimroz123
1 answer 22 views

Which capacitors are suitable for DC filter circuits?

asked Mar 8, 2018 in Electronics Engineering by Quiz
1 answer 25 views

Explain the requirements of elevator motor. State with reason best suitable motor for elevator.

asked Oct 13, 2018 in Industry Electrical Systems-II by Shimroz123
1 answer 6 views

Describe the importance of three wire and four wire configuration for RTD with suitable circuit diagram.

asked Sep 13, 2018 by Shimroz123
1 answer 11 views

For harnessing low variable water heads, the suitable hydraulic turbine with high percentage of reaction and runner adjustable vanes is  (A) Kaplan (B) Francis (C) Pelton (D) Impeller

asked May 25, 2018 in Power system by Shimroz123
1 answer 85 views

What is the difference between AC and DC drive?

asked Mar 10, 2018 in Control of electric drives by Quiz
0 answers 21 views

A dc shunt motor runs at 500 r.p.m at 220 V. A resistance of 4.5 Ω is added in series with the armature for speed control. The armature resistance is 0.5 ohms. The current to stall the motor will be (1) 44 A (2) 50 A (3) 44.4 A (4) 60 A  

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 22 views

A DC shunt motor has rated rpm of 480. Certain industrial application requires this motor to run at 540 rpm for some time. Which speed control will be desirable? A) Ward Leonard control B) Armature current control C) Field resistance control D) It is not possible to run the motor at more than the rated rpm 

asked Jun 17, 2018 in DC machine by Shimroz123
1 answer 16 views

Fractional pitch windings are used in DC machines to (A) Reduce copper losses (B) Improve cooling (C) Increase the generated emf (D) Reduce sparking

asked May 12, 2018 in DC machine by Shimroz123
1 answer 33 views

A large dc motor is required to control the speed of the blower from a 3 -phase ac source. The suitable ac to dc converter is, 3 -phase (a) Fully controlled bridge converter (b) Fully controlled bridge converter with freewheeling diode (c) Half controlled bridge converter (d) Converter pair in sequence control

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 26 views

A certain appliance uses 350 W. If it is allowed to run continuously for 24 days, how many kilowatt- hours of energy does it consume? A.20.16 kWh B.201.6 kWh C.2.01 kWh D.8.4 kWh

asked May 15, 2018 in Basic concepts by Shimroz123
1 answer 6 views

A certain appliance consumes 350 W. When it is allowed to run continuously for 24 days, it consumes electrical energy equal to: A. 20.16 kWh B. 201.6 kWh C. 2.01 kWh D. 8.4 kWh

asked Apr 12, 2018 in Electrical Engineering by Shimroz123
1 answer 8 views

A dc series motor driving and electric train faces a constant power load. It is running at rated speed and rated voltage. If the speed has to be brought down to 0.25 p.u. the supply voltage has to be approximately brought down to  (A) 0.75 p.u (B) 0.5 p.u (C) 0.25 p.u (D) 0.125 p.u

asked May 18, 2018 in DC motor by Shimroz123
1 answer 36 views

A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

asked May 3, 2018 in Electrical Machine by Shimroz123
0 answers 8 views

A separately excited dc generator is running at rated speed and at no load. If its field winding is suddenly connected to a dc source then rise in armature generated voltage is governed by (1) Armature time constant (2) Field time constant (3) Both (a) and (b) (4) Mechanical time constant

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 152 views

The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 30 views

The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

asked Mar 20, 2018 in Induction Machine by Shimroz123
1 answer 25 views

A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be (A) 1835 MW (B) 2280 MW (C) 2725 MW (D) 3257 MW

asked May 25, 2018 in Power system by Shimroz123
1 answer 97 views

"DC series motor is used for traction purpose." Justify your answer with any six characteristics.

asked Oct 12, 2018 in Industry Electrical Systems-II by Shimroz123
1 answer 65 views

Number of commutator bars for a 4-pole, 2-layer, DC lap winding with 24 slots and one conductor per layer is (A) 48 (B) 24 (C) 192 (D) 96

asked Apr 28, 2018 in Electrical Engineering by Shimroz123
0 answers 17 views

In the blocked state  (1) the processes waiting for I/O are found (2) the process which is running is found (3) the processes waiting for the processor are found (4) none of the above 

asked Apr 10, 2018 in Computer Engineering by Shimroz123
2 answers 72 views

State what is the significance of conducting phasing out test on a 3-phase transformer? Explain its procedure with a suitable connection diagram.

asked Sep 15, 2018 by Shimroz123
1 answer 67 views

With the help of suitable diagram, explain how humidity is measured with dry and wet bulb thermometer.

asked Sep 9, 2018 by Shimroz123
1 answer 22 views

Phantom loading for testing of energy meter is used (A) to isolate the current and potential circuits (B) to increase power loss during testing (C) for meters having low current ratings (D) to test meters having a large current rating for which loads may not be available

asked Apr 28, 2018 in Electronics Engineering by Shimroz123
1 answer 16 views

Unlike a shunt motor, it is difficult for a series motor to stall under heavy loading because?

asked Mar 26, 2018 in DC motor by Shimroz123
1 answer 15 views

For a long uncompensated line the limit to the line loading ill governed by?

asked Mar 27, 2018 in Power system by Shimroz123
1 answer 14 views

For speed control of ac drive, the preferred method using thyristors is  A) Phase control B) Integral cycle control C) Single pulse PWM control D) Sinusoidal PWM control

asked May 20, 2018 in Power Electronic Controlled Drives by Shimroz123
0 answers 23 views

The requirement of the gate drive circuits for power MOSFET and IGBT is (a) high source capability (b) high sink capability (c) both (a) and (b) (d) high voltage capability

asked Apr 14, 2018 in Electrical Engineering by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units
...