The values of L and C for a low pass filter with cut off frequency of 2.5 KHz and operating with a terminated load resistance of 450 Ohm are given by 

(a) 57.3 mH; 0.283 μF (b) 28.66 μH; 0.14 μF (c) 114.64 mH; 0.566 mF (d) 50.23 mH; 0.632 mF
in Electronics Engineering by

1 Answer

0 like 0 dislike

The values of L and C for a low pass filter with cut off frequency of 2.5 KHz and operating with a terminated load resistance of 450 Ohm are given by 57.3 mH; 0.283 μF