Can you help by answering this question?

Explain series switching control of AC load.

12 views
in Electronics Engineering by
The lossless line of characteristics impedance 300 Ohm is terminated in a pure resistance of 200 Ohm. The value of the standing wave ratio is 

(a) 1.5 (b) 0.67 (c) 1.0 (d) 1.25

1 Answer

0 votes
by

The lossless line of characteristics impedance 300 Ohm is terminated in a pure resistance of 200 Ohm. The value of the standing wave ratio is 1.5

Related questions

1 answer 18 views

A loss less line of characteristic impedance Z0 is terminated in pure reactance of –jZ0 value. VSWR is  (1) 10 (2) 2 (3) 1 (4) Infinity

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
1 answer 122 views

A 50Ω transmission line is terminated in an impedance of 20-j50. What will be the reflection coefficient? A) 0.69 B) 1.69 C) 6.9 D) 16.9 

asked Jun 18, 2018 in Electrical Engineering by Shimroz123
1 answer 18 views

The magnitude of the open-circuit and short circuit input impedance of a transmission line are 100 ohm and 25 ohm respectively. The characteristic impedance of line is:  (1) 25 ohm (2) 50 ohm (3) 75 ohm (4) 100 ohm

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
0 answers 26 views

If the RF transmission is terminated in its Characteristic impedance Z, which of the following statements is wrong : a. The input impedance of transmission line becomes Zc. b. The transmission line acts as an infinite long transmission line. c. The VSWR becomes one d. The VSWR becomes infinite

asked Apr 12, 2018 in Electronics Engineering by Shimroz123
1 answer 12 views

A transmission line is terminated at its characteristic impedance. The reflection coefficient is  (a) 1 (b) –1 (c) 0 (d) ∞

asked May 16, 2018 in Network Analysis by Shimroz123
1 answer 34 views

Two coils connected in series have resistance of 600 ohm and 300 ohm and temperature coefficients of 0.1% and 0.4% respectively.The resistance of the combination at 50oC will be 

asked Mar 31, 2018 in Electrical Engineering by Shimroz123
1 answer 12 views

The input impedance of a short circuited loss less transmission line of characteristic impedance 50 Ohm is

asked May 23, 2018 in Electric Power Transmission by Shimroz123
1 answer 78 views

A lossless radial transmission line with surge impedance loading?

asked Mar 27, 2018 in Power system by Shimroz123
1 answer 39 views

The rotor impedance of a slip ring induction motor is (0.1 + j0.6)Ohm/ ph . The resistance/ph to be inserted into rotor to get maximum torque at starting should be

asked May 3, 2018 in Electrical machine design by Shimroz123
1 answer 13 views

A travelling wave of surge resistance, Ro on a transmission line is terminated by a load resistance, RL. If RL > Ro then there is (A) no reflected wave (B) partial reflection of reversal of current only (C) partial reflection of reversal of voltage only (D) reflection of reversal of both current and voltage

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 11 views

A loss less line terminated with its surge impedance has

asked Mar 27, 2018 in Power system by Shimroz123
1 answer 5 views

As shown in the figure, 1 ohm resistance is connected across a source that has a load line v + i = 100. The current through the resistance is A) 25 A B) 50 A C) 100 A D) 200A

asked May 20, 2018 in Network Analysis by Shimroz123
1 answer 16 views

When an antenna of input resistance 73 ohm is connected to a 50-ohm line and if the losses are ignored then its efficiency will be nearly   (A) 0.19 (B) 0.81 (C) 0.97 (D) 1.19

asked May 17, 2018 in Electronics communication by Shimroz123
1 answer 16 views

 A single-phase transmission line of impedance j 0.8 ohm supplies a resistive load of 500 A at 300 V. The sending end power factor is?

asked Mar 27, 2018 in Power system by Shimroz123
1 answer 6 views

When a dominant mode wave guide not terminated in its characteristic impedance is excited with a 10 GHZ signal then if d is the distance between two successive minima of the standing wave in the guide then   (A) d = 1.5 cm (B) d is less then 1.5 cm (C) d is greater then 1.5 cm (D) d = 3 cm

asked May 17, 2018 in Electronics communication by Shimroz123
0 answers 52 views

A 220 kV, 3 phase transmission line is 60 km long. The resistance is 0.15 ohm / km and the inductance is 1.4 mH / km. Use the short line model to find the power at the sending end when the line is supplying a three phase load of 300 MVA at 0.8 pf lagging at 220 kV.  (A) 5.58MW (B) 80MW (C) 85.58MW (D) 74.42 MW 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 32 views

A 60 Hz, 320 km lossless line has Bending end voltage 1.0 p.u, The receiving end voltage on no load is?

asked Mar 27, 2018 in Power system by Shimroz123
0 answers 45 views

For a balanced three phase star connected load for which line voltage is 230V and per phase resistance and reactance is 6 Ohm and 8 Ohm respectively. Calculate: 1) phase voltage 2) line current 3) power factor 4) total power absorbed

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 20 views

A single-phase ac voltage source has 200 V rms and a system connected consumes an active power of 300 W. What is the reactive power consumed by the system if 2.5 A rms current is drawn ?  (a) 100 VAR (b) 200 VAR (c) 300 VAR (d) 400 VAR

asked Apr 23, 2018 in Electrical Engineering by Zeeshan
1 answer 12 views

An ammeter has a current change of 0—5A and its internal resistance is 0.2 ohm. In order to Change the range to 0-25 A, wear need to add a resistance of  A) 0.8 ohm in series with the meter B) 1.0 ohm in series with the meter C) 0.04 ohm in parallel with the meter D) 0.05 ohm in parallel with the meter

asked May 20, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 15 views

The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

asked Mar 21, 2018 in DC generator by Shimroz123
1 answer 33 views

The analog signal m(t) is given below m(t) = 4 cos 100 pt + 8 sin 200 pt + cos 300 pt, the Nyquist sampling rate will be: (1) 1/100 (2) 1/200 (3) 1/300 (4) 1/600 

asked May 28, 2018 in Analog electronics circuits by Shimroz123
1 answer 49 views

An A.C. voltage is impressed across a pure resistance of 3.5 ohms in parallel with a pure inductance of impedance of 3.5 ohms?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 17 views

The transient current in lossless L-C circuit when excited from an AC source is, sine wave  (a) Critically damped (b) Underdamped (c) Overdamped (d) Undamped

asked May 16, 2018 in Electronics Engineering by Shimroz123
1 answer 12 views

The standing wave ratio of a 75 Ω transmission line used to feed a 300 Ω resistive load will be _____.

asked May 29, 2018 in Electrical Engineering by Shimroz123
0 answers 17 views

A three phase 50 Hz, 400 kV transmission line is 300 km long. The line inductance is 0.97 mH/km per phase and capacitance is 0.0115 mF/km per phase. Assume a loss less line. Determine the line wavelength (a line phase constant).  (A) 1250 km (B) 6578 km (C) 4990 km (D) 2445 km 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ?

asked Apr 23, 2018 in Electrical Engineering by Zeeshan
1 answer 14 views

Twelve 1 ohm resistances are used as edge to form a cube. The resistance between two diagonally opposite corners of the cube is:  (1) 5/6 ohm (2) 1 ohm (3) 6/5 ohm (4) 3/2 ohm

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
1 answer 200 views

A 400/200 volts transformer has pu impedance of 0.05. The HV side voltage required to circulate full load current during short circuit test is

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 16 views

A 35 V dc supply is connected across a resistance of 600 ohm in series with an unknown resistance R. A voltmeter having a resistance of 1.2 kOhm is connected across 600 ohm resistances and reads 5 V. The value of resistance R shall be:

asked May 22, 2018 in Electrical Engineering by Shimroz123
1 answer 20 views

A coil of inductance 240 mH and resistance 75 Ohm is connected in parallel with a capacitor across a 30 V, variable frequency supply. The current drawn by the circuit is found to be minimum when the supply frequency is 1 kHz. The approximate values of Q-factor and bandwidth are, respectively (A) 40, 400 Hz (B) 10, 100 Hz (C) 20, 50 Hz (D) 50, 20 Hz

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 37 views

If a wire conductor of 0.2 ohm resistance is doubled in length, its resistance becomes?

asked Mar 25, 2018 in Basic concepts by Shimroz123
1 answer 14 views

The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

asked Apr 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 21 views

Surge impedance of overhead transmission line is normally in the order of (a) 1- 5 ohms (c) 300 - 500 ohms (b) 20 - 30 ohms (d) 300000 - 500000 ohms

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 185 views

For a 66 kV line having span of 200 meters between towers the approximate sag will be 2 m. If the span is double the sag will be:  (A) 1 m (B) 2 m (C) 4m (D) 8m

asked May 8, 2018 in Electric Power Distribution by Shimroz123
1 answer 19 views

A transmission line of 200 km has a certain A, B, C and D parameters. If the length is reduced to 60 km

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
1 answer 25 views

International ohm is defined in terms of the resistance of?

asked Mar 25, 2018 in Basic concepts by Shimroz123
1 answer 17 views

A long overhead transmission line is terminated by its characteristic impedance. Under this operating condition, the ratio of the voltage to the current at different points along the line will?

asked Mar 27, 2018 in Power system by Shimroz123
1 answer 12 views

With rise in temperature the resistance of pure metals?

asked Mar 25, 2018 in Basic concepts by Shimroz123
1 answer 191 views

A 10 km long line has a characteristic impedance of 400 ohms. If line length is 100 km, the characteristic impedance is: (1) 4000 Ω (2) 400 Ω (3) 40 Ω (4) 4 Ω

asked May 28, 2018 in Electric Power Transmission by Shimroz123
0 answers 15 views

Surge impedance loading (SIL) of power transmission line is the power delivered to a purely (a) inductive (b) capacitive (c) resistive load equal to surge impedance (d) none of these

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
0 answers 38 views

A balanced Delta connected load supplied with 440 V 50 Hz three phase AC supply has R=10 Ohm and L=0.6 mH in is each arm. Calculate line and phase current, active power.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
0 answers 26 views

A 200 V dc motor takes a field current of 2 A to generate a back emf of 180 V. If the field winding resistance is 80 Ω, the resistance of the shunt field regulator is (A) 10 Ω (B) 20 Ω (C) 100 Ω (D) 180 Ω

asked Jun 4, 2018 in Electrical Machine by Shimroz123
1 answer 19 views

A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 14 views

The values of L and C for a low pass filter with cut off frequency of 2.5 KHz and operating with a terminated load resistance of 450 Ohm are given by  (a) 57.3 mH; 0.283 μF (b) 28.66 μH; 0.14 μF (c) 114.64 mH; 0.566 mF (d) 50.23 mH; 0.632 mF

asked May 16, 2018 in Electronics Engineering by Shimroz123
1 answer 22 views

The armature resistance of a permanent magnet dc motor is 0.8 Ohm. At no load, the motor draws 1.5 A from a supply voltage of 25 V and runs at 1500 rpm. The efficiency of the motor while it is operating on load at 1500 rpm drawing a current of 3.5 A from the same source will be  (A) 48.0% (B) 57.1% (C) 59.2% (D) 88.8%

asked May 17, 2018 in Electrical Machine by Shimroz123
1 answer 60 views

If the insulation resistance of a cable of length 10 km is 1 mega ohm, its insulation resistance for 50 km length will be

asked May 8, 2018 in Electric Power Transmission by Shimroz123
1 answer 47 views

The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

asked Apr 25, 2018 in Instrumentation and control by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units
...