13 views
in Induction Machine by
For a single phase capacitor start induction motor, which of the following statements is valid? 

A) The capacitor is used for power factor improvement B) The direction of rotation can be changed by reversing the main winding terminals C) The direction of rotation cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

1 Answer

0 votes
by

For a single phase capacitor start induction motor, which of the following statements is valid? 

A) The capacitor is used for power factor improvement B) The direction of rotation can be changed by reversing the main winding terminals C) The direction of rotation cannot be changed D) The direction of rotation can be changed by interchanging the supply terminals

Related questions

1 answer 25 views

A capacitor-start single phase induction motor is switched on to supply with its capacitor replaced by an inductor of equivalent reactance value. It will?

asked Mar 20, 2018 in Induction Machine by Shimroz123
1 answer 20 views

In a capacitor start single-phase induction motor, the capacitor is connected in:  (A) series with the main winding (B) series with the auxiliary winding (C) series with both the windings (D) parallel with the auxiliary winding .

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
1 answer 11 views

A capacitor start, capacitor run single phase induction motor is basically a : -  a) ac series motor b) dc series motor c) 2 phase induction motor d) 3 phase induction motor

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 14 views

In the capacitor-start, capacitor-run single-phase induction motor (A) two capacitors are connected across the main winding (B) when the centrifugal switch opens, the permanent capacitor is left in the auxiliary winding circuit (C) when the centrifugal switch opens, the permanent capacitor is left in the main winding circuit (D) two capacitors are connected across the auxiliary winding.

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 6 views

Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by electricity authority  4. Ensures smooth run up to full load   Of these statements (a) 1, 2 and 3 are correct (b) 2, 3 and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

asked May 13, 2018 in Induction Machine by Shimroz123
0 answers 20 views

Draw and explain capacitor start capacitor run single phase induction motor.

asked Sep 1, 2018 by Quiz
1 answer 16 views

In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve (A) low starting torque (B) quick acceleration (C) high efficiency (D) reduced size

asked May 17, 2018 in Induction Machine by Shimroz123
1 answer 515 views

A single-phase induction motor with only the main winding excited would exhibit the following response at synchronous speed  (A) Rotor current is zero (B) Rotor current is non-zero and is at slip frequency (C) Forward and backward rotating fields are equal (D) Forward rotating field is more than the backward rotating field

asked May 18, 2018 in Induction Machine by Shimroz123
1 answer 26 views

The type of single-phase induction motor having the highest power factor at full load is (A) shaded pole type (B) split-phase type (C) capacitor-start type (D) capacitor-run type

asked May 17, 2018 in Induction Machine by Shimroz123
1 answer 14 views

Which statement out of the following is a wrong statement with regard to Induction motor? A) Auto-transformer starter is costlier to “direct on line” (DOL) starter B) DOL starter is used for motors up to 5 horse power only C) Auto transformer starter is used for motors up to 20 horse power only D) Star delta starter connects the motor first in delta at the time of starting then in star for running

asked Jun 17, 2018 in Induction Machine by Shimroz123
1 answer 11 views

The rotor frequency for a 3-phase 6-pole, 1000 r.p.m. induction motor with a slip of 0.04 is (a) 2 Hz (b) 4 Hz (c) 6 Hz (d) 8 Hz  

asked May 25, 2018 in Induction Machine by Shimroz123
1 answer 10 views

Which of the following statements is not valid in case of conductors in electrostatic fields? A) The static electric field intensity inside a conductor is zero B) The static electric field intensity at the surface of a conductor is everywhere directed normal to the surface C) The conductor surface is an equivalent potential surface D) None of the above

asked Jun 17, 2018 in Electrical Engineering by Shimroz123
0 answers 17 views

Compare resistance split phase induction motor with capacitor start induction motor.

asked Sep 1, 2018 by Quiz
1 answer 321 views

in a three-phase induction motor, the rotor field runs at the following speed with respect to the stator structure: 

asked May 22, 2018 in Induction Machine by Shimroz123
1 answer 13 views

In a 3-phase voltage source inverter used for speed control of induction motor, anti-parallel diodes are used across each switching device. The main purpose of diodes is to:

asked May 22, 2018 in Induction Machine by Shimroz123
1 answer 30 views

The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

asked Mar 20, 2018 in Induction Machine by Shimroz123
0 answers 27 views

Which of the following statements is CORRECT?  (A) A grid-connected induction generator always supplies lagging reactive power to the bus. (B) An overexcited synchronous motor draws current at a lagging power factor. (C) An under excited synchronous generator connected to an infinite bus works at a leading power factor. (D) The load angle of a synchronous machine is the angle between the excitation voltage and the load current.

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 12 views

In transformers, which ofthe following statements is valid?  A) In an open circuit test, copper losses are obtained while in short circuit test, core losses are obtained B) In an open circuit test, current is drawn at high power factor C) In a short circuit test, current is drawn at zero power factor D) In an open circuit test, current is drawn at low power factor

asked May 17, 2018 in Transformer by Shimroz123
1 answer 18 views

If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is:

asked May 22, 2018 in Induction Machine by Shimroz123
1 answer 10 views

The direction of rotation of a 3-phase induction motor is clockwise when it is supplied with 3-phase sinusoidal voltage having phase sequence A-B-C. For counter clockwise rotation of the motor, the phase sequence of the power supply should be  (A) B-C-A (B) C-A-B (C) A-C-B (D) B-C-A or C-A-B

asked May 17, 2018 in Induction Machine by Shimroz123
0 answers 11 views

The no~load current of a single phase induction motor is around _____% of full load current.  (1) 10 (2) 20 (3) 40 (4) 80

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
0 answers 24 views

The stator mmf and rotor mmf of a 3-phase induction motor (A) are equal (B) rotate with slip speed (C) are opposite but rotate with synchronous speed (D) rotate with the same rotor speed 

asked Jun 4, 2018 in Induction Machine by Shimroz123
1 answer 16 views

The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be?

asked Mar 26, 2018 in Induction Machine by Shimroz123
1 answer 13 views

A 3-phase induction motor is running at slip ‘s’. If its two supply leads are interchanged, then the operating slip at that instant will be:

asked May 22, 2018 in Induction Machine by Shimroz123
1 answer 20 views

A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: (1) Slip frequency (2) Supply frequency (3) Frequency corresponding to rotor speed (4) Zero

asked May 22, 2018 in Induction Machine by Shimroz123
1 answer 15 views

A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the starting developed torque to the full load torque is approximately equal to (A) 0.24 (B) 1.44 (C) 2.40 (D) 6.00

asked May 17, 2018 in Induction Machine by Shimroz123
1 answer 14 views

 As compared to a split phase motor, a capacitor start motor has _____.

asked May 29, 2018 in Electrical Machine by Shimroz123
1 answer 29 views

Which of the following statements is incorrect ? (A) Superposition theorem is useful for Linear and Non-linear circuit analysis when several sources are present in the circuit. (B) Thevenin's equivalent network consists of one voltage source in series with an impedance. (C) Norton's equivalent network consists of ... . (D) When both the load and source impedances are purely resistive, maximum power transfer is achieved under the condition : Load Resistance = Source Resistance

asked Apr 28, 2018 in Network Analysis by Shimroz123
1 answer 14 views

For a rotameter, which one of the following statements is TRUE? (A) The weight of the float is balanced by the buoyancy and the drag force acting on the float (B) The velocity of the fluid remains constant for all positions of the float (C) The measurement of volume flow rate of gas is not possible (D) The volume flow rate is insensitive to changes in density of the fluid

asked Apr 26, 2018 in Electronics Engineering by Shimroz123
1 answer 16 views

The synchronous speed for the seventh space harmonic mmf wave of a 3-phase, 8-pole, 50 Hz induction machine is  (A) 107.14 rpm in forward direction (B) 107.14 rpm in reverse direction (C) 5250 rpm in forward direction (D) 5250 rpm in reverse direction

asked May 17, 2018 in Induction Machine by Shimroz123
1 answer 58 views

Starting torque can be obtained in the case of a single phase induction motor with identical main and auxiliary windings by connecting:  (1) A capacitor across the mains (2) A capacitor in series with the machine (3) A capacitor is series with the auxiliary winding (4) Equal value capacitors in series with the main and the auxiliary windings

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
1 answer 20 views

In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
1 answer 18 views

What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
1 answer 23 views

In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in the same direction (C) the flux increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

asked Apr 28, 2018 in Electrical Machine by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units
...