The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 

(A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

1 Answer

0 votes
by

The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Related questions

1 answer 16 views

A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is  (A) 1.66 Nm (B) 95.50 Nm (C) 99.47 Nm (D) 624.73 Nm

asked May 17, 2018 in Induction Machine by Shimroz123
1 answer 29 views

A 3 phase, 400 volts, 50 Hz, 100 kW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of: (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

asked Apr 11, 2018 in Computer Engineering by Shimroz123
1 answer 32 views

A 3-phase, 4-pole, 50Hz induction motor runs at a speed of 1440 rpm. The rotating field produced by the rotor rotates at a speed of ________ rpm with respect to stator field. (A) 1500 (B) 0 (C) 1440 (D) 60

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 27 views

A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
0 answers 19 views

A delta connected 400 V, 50 Hz, 3-phase induction motor when started direct-on-line takes a starting current of 30 A. When the motor is started through a star-delta starts, the starting current will be (1) 3A (2) 10 A (3) 15 A (4) 30 A 

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 33 views

A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the core losses are 1200 W. The air-gap power of the motor will be (A) 23.06 kW (B) 24.11 kW (C) 25.01 kW (D) 26.21 kW

asked May 17, 2018 in Electrical Machine by Shimroz123
1 answer 34 views

A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 148 views

A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is

asked May 3, 2018 in Electric Power Transmission by Shimroz123
1 answer 18 views

If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is:

asked May 22, 2018 in Induction Machine by Shimroz123
1 answer 21 views

A centre zero ammeters connected in the rotor circuit of a 6-pole 50 Hz induction motor makes 30 oscillations in one minute. The rotor speed is

asked Apr 1, 2018 in Electrical Engineering by Shimroz123
1 answer 27 views

The rotor power output of a 3 -phase induction motor is 15 kW and the corresponding slip is 4%. The rotor copper losses will be: (A) 600 W (B) 625 W (C) 650 W (D) 700 W

asked Apr 11, 2018 in Computer Engineering by Shimroz123
1 answer 14 views

A 4-pole induction motor, supplied by a slightly unbalanced three-phase 50 Hz source, is rotating at 1440 rpm. The electrical frequency in Hz of the induced negative sequence current in the rotor is  (A) 100 (B) 98 (C) 52 (D) 48

asked May 17, 2018 in Induction Machine by Shimroz123
1 answer 22 views

The stator of a 415V, 50 Hz, 4-pole slip ring Induction Motor is excited by rated frequency with slip rings open circuited. The rotor is made to rotate at a speed of 600 rpm in the opposite direction to the normal direction, The frequency of induced voltage across slip ring is A) 30 Hz B) 70 Hz C) 20 Hz D) 35 Hz

asked Jun 17, 2018 in Induction Machine by Shimroz123
1 answer 32 views

A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for

asked Apr 29, 2018 in Electrical Machine by Shimroz123
0 answers 11 views

A 3-phase, 50 Hz, 500 V induction motor develops 20 hp at slip of 5%. Mechanical losses are 1 hp, and stator loss is 1 kW. The efficiency will be   (a) 95.3% (b) 90.5% (c) 91.3% (d) 85.3% 

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
0 answers 22 views

Calculate the approximate locked rotor current of a 3 phase induction motor having a rating of 500 Hp, 2300 V.  (A) 130 A (B) 39 A (C) 390 A (D) 780 A 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 17 views

The starting torque of a V/f controlled inverter-fed 3-phase induction motor operating at 25 Hz as compared with the same motor operating at 50 Hz is (A) more (B) double (C) equal (D) less 

asked Jun 4, 2018 in Electrical Machine by Shimroz123
0 answers 19 views

The power input to the rotor of a 400V, 50 Hz 6 pole three phase induction motor is 20kW. The slip is 3%. The frequency of rotor currents is: (A) 1 Hz (B) 1.5 Hz (C) 2 Hz (D) 1 2 Hz

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
1 answer 60 views

The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 

asked Apr 29, 2018 in Electrical Machine by Shimroz123
0 answers 41 views

A 0.5 Hp, 6 pole wound rotor induction motor is excited by a 3 phase 60 Hz source. Calculate the frequency of the rotor current at standstill.  (A) 50 Hz (B) 30 Hz (C) 60 Hz (D) 120 Hz 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

asked Apr 28, 2018 in Power Electronics by Shimroz123
1 answer 18 views

A three-phase, 440 V, 50 Hz ac mains fed thyristor bridge is feeding a 440 V dc, 15 kW, 1500 rpm separately excited dc motor with a ripple free continuous current in the dc link under all operating conditions, Neglecting the losses, the power factor of the ac mains at half the rated speed is  (A) 0.354 (B) 0.372 (C) 0.90 (D) 0.955

asked May 18, 2018 in Power electronics converters by Shimroz123
1 answer 38 views

In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

asked Apr 28, 2018 in Power Electronics by Shimroz123
1 answer 7 views

A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is  (A) 2.43 A (B) 1.65 A (C) 1.22 A (D) 1.0 A

asked May 18, 2018 in Power electronics converters by Shimroz123
1 answer 42 views

A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume constant power input to the shaft. The accelerating torque in the generator in MNm at the time of fault will be  (A) 1.528 (B) 1.018 (C) 0.848 (D) 0.509

asked May 25, 2018 in Power system by Shimroz123
1 answer 28 views

A separately excited d.c. machine is coupled to a 50 Hz, three-phase, 4-pole induction machine as shown in the figure. The Dc machine is energized first and the machines rotate at 1 600 1pm. Subsequently the induction machine is also connected to a 50 Hz, three phase source, the phase sequence being consistent with the direction of rotation. In steady state

asked May 20, 2018 in DC machine by Shimroz123
0 answers 24 views

A single phase 230 V/ 150 V , 1 kVA, 50 Hz transformer is supplied by 230 V AC supply. Find the full load primary and secondary current. 

asked Sep 1, 2018 by Quiz
1 answer 29 views

An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is (A) 5.06 kW (B) 0.3 kW (C) 100 kW (D) 83.33 kW

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 15 views

A 3-phase induction motor under locked rotor condition and with stator supply, induces (A) small voltage at slip frequency (B) large voltage at rotor frequency (C) zero voltage at zero frequency (D) large voltage at slip frequency

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 33 views

A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

asked May 8, 2018 in Electrical Machine by Shimroz123
1 answer 34 views

An 8 pole wound rotor induction motor operating on 60 Hz supply is driven at 1800 r.p.m. by a prime mover in the opposite direction of revolving magnetic field. The frequency of the rotor current is (a) 30 Hz (b) 60 Hz (c) 120 Hz (d) 180 Hz 

asked May 25, 2018 in Induction Machine by Shimroz123
1 answer 15 views

In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :

asked Apr 29, 2018 in Electrical Machine by Shimroz123
1 answer 16 views

The synchronous speed for the seventh space harmonic mmf wave of a 3-phase, 8-pole, 50 Hz induction machine is  (A) 107.14 rpm in forward direction (B) 107.14 rpm in reverse direction (C) 5250 rpm in forward direction (D) 5250 rpm in reverse direction

asked May 17, 2018 in Induction Machine by Shimroz123
0 answers 54 views

A 1-phase, 7.46 kW motor is supplied from a 400 V, 50 Hz A.C mains. Its efficiency is 85% and power factor is 0.8 lagging. Calculate the KVA input (1) 9.56 kVA (2) 5.4 Kva (3) 10.97 kVA (4) 8.6 kVA 

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
0 answers 38 views

A balanced Delta connected load supplied with 440 V 50 Hz three phase AC supply has R=10 Ohm and L=0.6 mH in is each arm. Calculate line and phase current, active power.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 16 views

The number of poles in a phase induction motor at 50 Hz and running at 1500 rpm will be?

asked Mar 26, 2018 in Induction Machine by Shimroz123
1 answer 24 views

A 6 pole 3-phase wound-rotor induction machine is driven by another machine at 1800 rpm. The rotor of the induction machine is connected to a 50Hz system. If the mechanical rotation of the rotor is in the same direction as the rotor winding flux rotation, then frequency of the stator voltage will be

asked Apr 1, 2018 in Electrical Engineering by Shimroz123
1 answer 57 views

A 6-pole, 50Hz, 3-φ induction motor is running at 950 r.p.m. and has Cu loss of 5kW. The rotor input is (a) 10 kW (b) 95 kW (c) 100 kW (d) 9.5 kW 

asked May 25, 2018 in Induction Machine by Shimroz123
1 answer 11 views

The rotor frequency for a 3-phase 6-pole, 1000 r.p.m. induction motor with a slip of 0.04 is (a) 2 Hz (b) 4 Hz (c) 6 Hz (d) 8 Hz  

asked May 25, 2018 in Induction Machine by Shimroz123
0 answers 45 views

For a balanced three phase star connected load for which line voltage is 230V and per phase resistance and reactance is 6 Ohm and 8 Ohm respectively. Calculate: 1) phase voltage 2) line current 3) power factor 4) total power absorbed

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 18 views

What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
0 answers 15 views

A 50 Hz, 3—phase induction motor has a full load speed of 1440 rpm. The number of poles of the motor is:   (A)4 (8)6 (0)12  (D)8

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
1 answer 13 views

The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be

asked Mar 27, 2018 in Power system by Shimroz123
1 answer 21 views

In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is (A) 0.2 Ω (B) 0.3 Ω (C) 0.4 Ω (D) 0.5 Ω

asked Apr 28, 2018 in Electrical Machine by Shimroz123
0 answers 20 views

If the supply frequency of a 3-phase induction motor is ‘f’, then frequency of rotor emf at motor slip ‘s’ will be   (a) sf (b) (1 – s)f (c) f/s (d) None of these 

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
0 answers 24 views

A 750 Hp, 250 V, 1200 r/min DC motor is connected to a 208 V, 3 phase, 60 Hz, line using a 3 phase bridge converter. The full load armature current is 2500 A and the armature resistance is 4 m ohm. Calculate the required firing angle under rated full load conditions.  (A) 45 deg (B) 208 deg (C) 27 deg (D) 32 deg 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 52 views

The corona loss on a particular system at 50 Hz is 1 kw/phase per km. The corona loss on the same system with supply frequency 25 Hz will be?

asked Mar 27, 2018 in Power system by Shimroz123
1 answer 17 views

A 3-phase induction motor is driving a constant torque load at rated voltage and frequency. If both voltage and frequency are halved, following statements relate to the new condition if stator resistance, leakage reactance and core loss are ignored  1. The difference between synchronous speed and actual speed remains same 2. The airgap flux remains same 3. The ... . slip remains same Among the above, current statements are  (A) All (B) 1, 2 and 3 (C) 2, 3 and 4 (D) 1 and 4

asked May 18, 2018 in Induction Machine by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,450 questions

7,047 answers

132 comments

3,084 users

...