A 4-pole, 3-phase, double-layer winding is housed in a 36-slot stator for an ac machine with 60o phase spread. Coil span is 7 short pitches. Number of slots in which top and bottom layers belong to different phases is 

(A) 24 (B) 18 (C) 12 (D) 0

Please log in or register to answer this question.

1 Answer

0 votes
answered by

A 4-pole, 3-phase, double-layer winding is housed in a 36-slot stator for an ac machine with 60o phase spread. Coil span is 7 short pitches. Number of slots in which top and bottom layers belong to different phases is 24 