A three phase fully controlled bridge converter is feeding a load drawing a constant and ripple free load current of 10 A at a firing angle of 30o. The approximate Total harmonic Distortion (%THD) and the rms value of fundamental component of input current will respectively be 

(A) 31% and 6.8 A (B) 31% and 7.8 A (C) 66% and 6.8 A (D) 66% and 7.8 A

in Power electronics converters by

1 Answer

0 like 0 dislike

A three phase fully controlled bridge converter is feeding a load drawing a constant and ripple free load current of 10 A at a firing angle of 30o. The approximate Total harmonic Distortion (%THD) and the rms value of fundamental component of input current will respectively be 31% and 7.8 A