Can you help by answering this question?

Real power flow in transmission lines is controlled by

21 views
in Switchgear And Protection by
For complete protection ofa 3— phase line:

(1) Three phase and three—earth fault relays are required

(2) Three phase and two—earth fault relays are required

(3) Two phase and two—earth fault relays are required

(4) Two phase and one-earth fault relays are required

Your answer

Thanks for your contribution. Feel free to answer this question. Please avoid short answer. Your answer is most welcome. Be genuine.

Upload image or document:

Your name to display (optional):
Privacy: Your email address will only be used for sending these notifications.
Anti-spam verification:
Are you a robot ? (Y = Yes / N = No)
To avoid this verification in future, please log in or register.

1 Answer

0 votes
by

For complete protection ofa 3— phase line: Two phase and one-earth fault relays are required

Related questions

1 answer 42 views

For complete protection of a three-phase line: A) three Phase relays and three Earth fault relays are required B) three Phase relays and two Earth fault relays are required C) two Phase relays and two Earth fault relays are required D) two Phase relays and one Earth fault relay are required

asked Jun 17, 2018 in Switchgear And Protection by Shimroz123
0 answers 46 views

For a balanced three phase star connected load for which line voltage is 230V and per phase resistance and reactance is 6 Ohm and 8 Ohm respectively. Calculate: 1) phase voltage 2) line current 3) power factor 4) total power absorbed

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 10 views

For equilateral spacing of conductors of an untrasposed 3-phase line, we have?

asked Mar 27, 2018 in Power system by Shimroz123
1 answer 29 views

 For the protection of parallel feeders fed from one end, the relays used are: A) non-directional relays at the source-end and directional relays at the load-end B) non-directional relays at both the ends C) directional relays at the source-end and non-directional at the load-end D) directional relays at both the ends

asked Jun 4, 2018 in Switchgear And Protection by Shimroz123
1 answer 20 views

A loss of excitation protection scheme for large generating unit employs A) under frequency relays B) offset Mho relay C) reactance relay D) percentage differential relay

asked May 24, 2018 in Switchgear And Protection by Shimroz123
1 answer 53 views

A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

asked May 8, 2018 in Switchgear And Protection by Shimroz123
1 answer 366 views

A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

asked May 1, 2018 in Switchgear And Protection by Shimroz123
1 answer 66 views

For protection of rotating machines against lightning surges _______ is used.  (1) lightning arrester (2) capacitor (3) combination of lightning arrester and capacitor (4) lightning conductor and arrester

asked Apr 30, 2018 in Switchgear And Protection by Shimroz123
1 answer 26 views

Reactance relay is normally preferred for protection against

asked Apr 29, 2018 in Switchgear And Protection by Shimroz123
1 answer 49 views

Surge absorbers are used for protection against

asked Apr 26, 2018 in Switchgear And Protection by Shimroz123
1 answer 18 views

State the nature of protection provided for following types of faults; 1) Over voltage 2) Under voltage 3) High air pressure in air circuit 4) Low air pressure in air circuit

asked Sep 2, 2018 by Shimroz123
1 answer 73 views

The number of cycles in which a high speed circuit breaker can complete its operation is  (A) 3 to 8 (B) 10 to 18 (C) 20 to 30 (D) 40 to 50

asked May 8, 2018 in Switchgear And Protection by Shimroz123
1 answer 19 views

A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, j0.1 and j0.04 respectively. The neutral of the alternator is connected to ground through an inductive reactor of j0.05 p.u. The per unit positive-, ... The voltage of the alternator neutral with respect to ground during the fault is  (A) 513.8 V (B) 889.9 V (C) 1112.0 V (D) 642.2 V

asked May 25, 2018 in Power system by Shimroz123
1 answer 26 views

A 500 MW, 3-phase, Y-connected synchronous generator has a rated voltage of 21.5 kV at 0.85 p.f. The line current when operating at full load rated conditions will be  (A) 13.43 kA (B) 15.79 kA (C) 23.25 kA (D) 27.36 kA

asked May 17, 2018 in Synchronous machine by Shimroz123
1 answer 63 views

The corona loss of a 3-phase transmission line is 100 kW at 60 kV/phase and 25 kW at 50 kV/phase. The disruptive critical voltage is (A) 40 kV (B) 43.6 kV (C) 49.6 kV (D) 50 kV

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 27 views

A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ?

asked Apr 23, 2018 in Electrical Engineering by Zeeshan
0 answers 19 views

A delta connected 400 V, 50 Hz, 3-phase induction motor when started direct-on-line takes a starting current of 30 A. When the motor is started through a star-delta starts, the starting current will be (1) 3A (2) 10 A (3) 15 A (4) 30 A 

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
0 answers 52 views

A 220 kV, 3 phase transmission line is 60 km long. The resistance is 0.15 ohm / km and the inductance is 1.4 mH / km. Use the short line model to find the power at the sending end when the line is supplying a three phase load of 300 MVA at 0.8 pf lagging at 220 kV.  (A) 5.58MW (B) 80MW (C) 85.58MW (D) 74.42 MW 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 20 views

A Phase shift transformer is designed to control 150 MVA on a 230 kV, 3 phase line. The phase angle is variable between zero and 15 deg. Calculate the approximate basic power rating of the transformer.  (A) 150 MVA (B) 56 MVA (C) 75 MVA (D) 750 MVA 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 24 views

A 750 Hp, 250 V, 1200 r/min DC motor is connected to a 208 V, 3 phase, 60 Hz, line using a 3 phase bridge converter. The full load armature current is 2500 A and the armature resistance is 4 m ohm. Calculate the required firing angle under rated full load conditions.  (A) 45 deg (B) 208 deg (C) 27 deg (D) 32 deg 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 17 views

A 3 Phase, 60 Hz generator connected in Y connection, generates a line to line voltage of 23900 V. Calculate the peak line voltage.  (A) 13800 V (B) 33800 V (C) 42300 V (D) 23900 V 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
4 answers 173 views

What is the voltage in 3 phase line?

asked Dec 22, 2017 in Fundamentals of electrical power systems by Quiz
1 answer 156 views

For a 15-bus power system with 3 voltage controlled buses, the size of Jacobian matrix is

asked Apr 27, 2018 in Switchgear And Protection by Shimroz123
1 answer 22 views

The surge impedance for over head line is taken as  (1) 10-20 ohms (2) 50-60 ohms (3) 100-200 ohms (4) 1000-2000 ohms

asked May 1, 2018 in Switchgear And Protection by Shimroz123
1 answer 19 views

Reactance relays are employed for Phase faults in : (A) Short lines (B) Medium lines (C) Long lines (D) Any line

asked May 12, 2018 in Switchgear And Protection by Shimroz123
1 answer 165 views

Which type of protection is provided on a generator to protect against stator insulation failure? A) Differential protection B) Overcurrent relay C) Thermocouple actuated alarm D) Reverse power relay

asked Jun 4, 2018 in Switchgear And Protection by Shimroz123
0 answers 55 views

Protection of transformer from all types of faults is by using (A) over current relay (B) differential relay (C) distance relay (D) Buchholz relay

asked Jun 4, 2018 in Switchgear And Protection by Shimroz123
1 answer 20 views

The type of backup protection scheme widely used in the field is (A) Relay backup (B) Breaker backup (C) Remote backup (D) Auxiliary backup

asked May 12, 2018 in Switchgear And Protection by Shimroz123
1 answer 21 views

Blind spot is a point in the zones of protection where

asked May 8, 2018 in Switchgear And Protection by Shimroz123
1 answer 131 views

Primary and Backup Protection

asked Aug 9, 2017 in Switchgear And Protection by Zeeshan
1 answer 9 views

Draw and explain star delta starter for 3 phase induction motor

asked 5 hours ago in AC machine by Shimroz123
1 answer 2 views

Explain DOL starter used for 3 phase induction motor.

asked 6 hours ago in AC machine by Shimroz123
2 answers 145 views

Explain the suitability of 3-phase induction motor for traction service. 

asked Oct 13, 2018 in Industry Electrical Systems-II by Shimroz123
2 answers 60 views

for Delta-Star connection of 3-phase transformer: i) Draw the connection diagram ii) List any two advantages of this connection iii) State its area of application. 

asked Sep 15, 2018 by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,530 questions

7,129 answers

135 comments

3,090 users

...