When two transformer of different kVA rating are connected in parallel they share the load in proportion to their respective kVA rating only when their:

1 Answer

0 votes
by

When two transformer of different kVA rating are connected in parallel they share the load in proportion to their respective kVA rating only when their: P u impedance are equal

Related questions

1 answer 18 views

Two transformers are to be operated in parallel such that they share load in proportion to their kVA ratings. The rating of the first transformer is 500 kVA ratings. The rating of the first transformer is 500 kVA and its pu leakage impedance is 0.05 pu. If the rating of second transformer is 250 kVA, its pu leakage impedance is  (A) 0.20 (B) 0.10 (C) 0.05 (D) 0.025

asked May 17, 2018 in Transformer by Shimroz123
1 answer 25 views

Two transformers operating in parallel will share the load depending upon their

asked May 12, 2018 in Transformer by Shimroz123
1 answer 8 views

Two transformers having the same p.u. impedance connected in parallel share the connected load (A) equally (B) in proportion to the respective ratings (C) in proportion to the voltage ratio (D) in proportion to the zero phase displacement

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 21 views

What should be kVA rating of each transformer in V-V bank when three phase balanced load is 40 kVA ? (A) 19 (B) 28 (C) 37 (D) 23

asked May 13, 2018 in Electrical Engineering by Shimroz123
1 answer 17 views

Two transformers with identical voltage ratings are working in parallel to supply common load. The percentage impedance of one transformer is higher compared to that of other. The load sharing between the two transformer will: (1) Be proportional to their percentage impedance (2) Be independent of their percentage impedance (3) Be inversely proportional of their respective impedance (4) Depend on the resistance to leakage reactance ratio of each transformer

asked May 22, 2018 in Transformer by Shimroz123
1 answer 11 views

Three capacitors 15µf, 18µf and 12µf are connected in a circuit. Find equivalent capacitance when they are connected in – 1) Series 2) Parallel

asked Sep 2, 2018 by Shimroz123
0 answers 42 views

When two synchronous machines are connected in parallel the synchronizing power tends to (A) accelerate the faster machine (B) retard the faster machine (C) retards the slower machine (D) pull the faster machine out of step

asked Jun 4, 2018 in Synchronous machine by Shimroz123
1 answer 17 views

A single-phase, 50 kVA, 250 V/500 V two winding transformer has an efficiency of 95% at full load, unity power factor. If it is re-configured as a 500 V/750 V auto-transformer, its efficiency at its new rated load at unity power factor will be  (A) 95.752% (B) 97.851% (C) 98.276% (D) 99.241%

asked May 17, 2018 in Transformer by Shimroz123
1 answer 24 views

A single-phase transformer has a turns ratio of 1 :2 and is connected to a purely resistive load as shown in the figure. The magnetizing current drawn is 1A, and the secondary current is 1A. Ifcore losses and leakage reactances are neglected, the primary current is  A)1.41A B)2A C) 2.24A D)3A

asked May 20, 2018 in Transformer by Shimroz123
1 answer 13 views

The kVA rating required for a transformer that must handle a maximum load current of 8 A with a secondary voltage of 2 kV will be: A. 4 kVA B. 0.25 kVA C. 16 kVA D. 8 kVA

asked Apr 12, 2018 in Electrical Engineering by Shimroz123
2 answers 26 views

How will the total capacitance change, when two capacitors are connected in parallel?

asked May 29, 2018 in Capacitor by Shimroz123
0 answers 82 views

Three single phase transformers each with 10 kVA rating are connected in a closed delta arrangement. If one transformer is taken out, the output capacity of the system will be (a) 20 kVA (b) 8.66 kVA (c) 17.32 kVA (d) 10 kVA

asked May 25, 2018 in Single phase transformer by Shimroz123
1 answer 10 views

When two 100 kΩ resistors are connected in parallel, net resistance is

asked May 15, 2018 in Electrical Engineering by Shimroz123
1 answer 14 views

Two incandescent light bulbs of 40 Wand 60 W rating are connected in series across the mains, then .  A) The bulbs together consume 100 W B) The bulbs together consume 50 W C) The 60 W bulb glows brighter D) The 40 W bulb glows brighter

asked May 20, 2018 in Network Analysis by Shimroz123
1 answer 26 views

When the phase difference between two sinusoidal quantities is 90° they are said to be ______ A) Phase right angle B) Phase quadrature C) Phase sinuright D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
1 answer 13 views

A 500 kVA, 3-phase transformer has iron losses of 300 W and full load copper losses of 600 W. The percentage load at which the transformer is expected to have maximum efficiency is  (A) 50.0% (B) 70.7% (C) 141.4% (D) 200.0%

asked May 17, 2018 in Transformer by Shimroz123
0 answers 29 views

When two alternators A and B are operating in parallel, the increase in steam supply to alternator A will cause the active power output of (1) Alternator A to be decreased and alternator B to be increased (2) Alternators A and B is not affected (3) Alternators A and B is increased (4) Alternator A to be increased and alternator B to be decreased

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 23 views

Two 550 kVA alternator operate in parallel to supply the following loads I. 250 KW at 0.95 p.f. lagging II. 100 KW at 0.85 p.f. leading One machine is supplying 200 KW at 0.9 p.f. lagging. The p.f. of other machine must be

asked Apr 1, 2018 in Electrical Engineering by Shimroz123
1 answer 21 views

Two single-phase 150 kVA, 7200/ 600 volt transformers are connected in open-delta. The maximum three-phase load that they can carry is: A) 300 kVA B) 75 kVA C) 259 kVA D) 249 kVA

asked Jun 4, 2018 in Single phase transformer by Shimroz123
0 answers 21 views

A large transformer operating at no load draws an exciting current Io of 5A, when the primary is connected to a 120 V, 60 Hz source. From a wattmeter test, it is known that iron losses are equal to 180 W. Calculate the reactive power absorbed by the core.  (A) 600 var (B) 572 var (C) 180 var (D) 360 var 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 121 views

Two heater wires of equal length are connected first in series and then in parallel. The ratio of heat generated from series to parallel connection will be (a) 4 : 1 (b) 2 : 1 (c) 1 : 2 (d) 1 : 4

asked May 25, 2018 in Electrical Engineering by Shimroz123
0 answers 18 views

When ‘n’ resistances each of value ‘r’ are connected in parallel, then the resultant resistance is ‘x’. When these ‘n’ resistances are connected in series, total resistance is  (A) n2X (B) X/n (C) n2/X (D) nX2

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 14 views

Two resistors are said to be connected in series when?

asked Mar 25, 2018 in Basic concepts by Shimroz123
1 answer 22 views

When four resistances of 2W 1W; 5W 2W; 10W 5W and 15W 10 W are connected in parallel, the greatest power is absorbed by • 2 W, 1 W • 5 W, 2 W • 10 W, 5W • 15 W, 10 W

asked May 13, 2018 in Electrical Engineering by Shimroz123
1 answer 23 views

When n resistances each of value r are connected in parallel, then resultant resistance is x. When these n resistances are connected in series, total resistance is

asked Mar 31, 2018 in Electrical Engineering by Shimroz123
1 answer 22 views

The kVA rating of Three-phase transformer with Voltage = 200V and Current = 100A will be :  (A) 34.64 kVA (B) 75 kVA (C) 20 kVA (D) None of the above

asked May 8, 2018 in Electrical Engineering by Shimroz123
0 answers 20 views

If two 3-phase transformers with unequal voltage ratios are connected in parallel, the result is (A) circulating current on no-load (B) no circulating current on no-load (C) dead short-circuit (D) equal no-load secondary emfs 

asked Jun 4, 2018 in Electrical Machine by Shimroz123
2 answers 25 views

Three lamps are connected in parallel across a 120 Volt source. If one lamp burns out, the remaining two will be: A. Glow dimmer B. Glow brighter C. Not light D. Glow with the same brightness as before

asked Apr 12, 2018 in Electrical Engineering by Shimroz123
3 answers 146 views

Why Transformer rating is given in kVA?

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
2 answers 65 views

Transformer generally rated in KVA

asked Dec 7, 2017 in Electrical Engineering by jihadio k jeeja
1 answer 14 views

A 1100 kVA, 11 kV/1.1 kV conventional two-winding transformer is connected as a 12.1 kV/11 kV step-down auto-transformer. The rating of the auto-transformer is (A) 1000 kVA (B) 1100 kVA (C) 11000 kVA (D) 12100 kVA

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 11 views

When two alternators are operating in parallel, the cause for circulating current is (A) increase in the excitation of one machine (B) increase in the driving torque of one machine (C) reduction in angular velocity of one machine (D) identical speed/load characteristics of both machines

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 15 views

In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?

asked Mar 19, 2018 in Transformer by Shimroz123
0 answers 40 views

If an energy meter disc makes 10 revolutions in 100 seconds when a load of 450W is connected to it, the meter constant in revolutions per kWh is  A) 1000 B) 500 C) 1600 D) 800

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
1 answer 73 views
1 answer 18 views

When three resistors with unequal values are connected in parallel, _______ A) The current across the resistors is the same  B) The voltage drop across the resistors is the same C) The voltage drops across the resistors is proportional to the resistance of each resistor D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
0 answers 58 views

Two d.c. series motors connected in series are driving a mechanical load. If the motors are connected in parallel to drive the same load, the speed becomes  (a) slightly less than double (b) slightly less than half (c) slightly more than double (d) slightly more than half 

asked May 25, 2018 in Electrical Engineering by Shimroz123
1 answer 25 views

A single-phase transformer has no-load loss of 64 W, as obtained from an open circuit test. When a short-circuit test is performed on it with 90% of the rated currents flowing in its both LV and HV windings, he measured loss is 81 W. The transformer has maximum efficiency when operated at  (A) 50.0% of the rated current (B) 64.0% of the rated current (C) 80.0% of the rated current (D) 88.8% of the rated current

asked May 17, 2018 in Transformer by Shimroz123
0 answers 20 views

One 200 V, 100 W bulb is connected in series with primary of a 200 V, 10 kVA transformer. If its secondary is kept open circuited, then the bulb would have (1) Full brightness (2) Poor brightness (3) A little less than full brightness (4) More than full brightness 

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 87 views

There resistors of 3Ω, 10Ω, and 15Ω are connected in parallel to a 30 V circuit the current that will flow through the 3Ω resistor is 

asked Mar 29, 2018 in Electronics Engineering by Shimroz123
1 answer 23 views

Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, respectively. Then the system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 8 views

A two-phase generator is connected to two 90Ω load resistors. Each coil generates 120 V ac. The value of current flowing through the common neutral line will be: A. 1.33 A B. 1.88 A C. 2.66 A D. 1.77 A

asked Apr 12, 2018 in Electrical Engineering by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units
...