in Electric Power Transmission by
For a transmission line open circuit and short circuit impedances are 20 Ω and 5 Ω. Then characteristic impedance is: (1) 100 Ω (2) 50 Ω (3) 25 Ω (4) 10 Ω

Your answer

Thanks for your contribution. Feel free to answer this question. Please avoid short answer. Your answer is most welcome. Be genuine.

Upload image or document:

Your name to display (optional):
Privacy: Your email address will only be used for sending these notifications.
Anti-spam verification:
Are you a robot ? (Y = Yes / N = No)
To avoid this verification in future, please log in or register.

1 Answer

0 votes
by

For a transmission line open circuit and short circuit impedances are 20 Ω and 5 Ω. Then characteristic impedance is: 10 Ω

Related questions

1 answer 18 views

The magnitude of the open-circuit and short circuit input impedance of a transmission line are 100 ohm and 25 ohm respectively. The characteristic impedance of line is:  (1) 25 ohm (2) 50 ohm (3) 75 ohm (4) 100 ohm

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
1 answer 13 views

The input impedance of a short circuited loss less transmission line of characteristic impedance 50 Ohm is

asked May 23, 2018 in Electric Power Transmission by Shimroz123
0 answers 40 views

The ratio of air-gap line voltage from open-circuit characteristic and armature current from short-circuit characteristic for a particular value of the field current in a synchronous generator is (A) synchronous reactance (B) synchronous impedance (C) unsaturated synchronous reactance (D) unsaturated synchronous impedance 

asked Jun 4, 2018 in Synchronous machine by Shimroz123
1 answer 13 views

To find current in a resistance connected in a network, Thevenin's theorem is used VTH = 20 V and RTH = 5 Ω. The current through the resistance: (1) is 4 A (2) is 4 A or less (3) is less than 4 A (4) May be 4 A or less or more than 4 A

asked May 29, 2018 in Network Analysis by Shimroz123
1 answer 5 views

If in a short transmission line, resistance and inductance are found to be equal and regulation appear. to be zero, then the load will?

asked Mar 27, 2018 in Power system by Shimroz123
0 answers 22 views

If diameter of each conductor of a transmission line is ‘d’, then the diameter of n-layer stranded conductor will be (a) (2n – 1) d (b) (2n + 1) d (c) (3n – 1) d (d) (3n + 1) d 

asked May 26, 2018 in Electric Power Transmission by Shimroz123
1 answer 23 views

What is the total resistance if 5 resistors of 20 Ω each are connected in series? A) 100 Ω B) 4 Ω C) 20 Ω D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
2 answers 95 views

The sending end and receiving end voltages of a three-phase transmission line are 10 kV/ph and 9.5 kV/ph, respectively. If the resistance drop is 150 V/ph and receiving end power factor is 0.8, the sending end power factor is (A) 0.745 lagging (B) 0.775 lagging (C) 0.8 lagging (D) 0.85 lagging

asked Apr 28, 2018 in Power system by Shimroz123
1 answer 40 views

For a two -port reciprocal network, the three transmission parameters are A = 4, B = 7 and C = 5. What is the value of D ?  (a) 9.5 (b) 9.0 (c) 8.5 (d) 8.0

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 115 views

In a transmission line if booster transformers are to be used, preferred location will be  (A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

asked May 8, 2018 in Electric Power Transmission by Shimroz123
3 answers 128 views

Describe the difference between an open circuit and a short circuit.

asked Jun 29 by Shimroz123
1 answer 41 views

A field excitation of 20 A in a certain alternator results in an armature current of 400 A in short circuit and a terminal voltage of 2000 V on open circuit. The magnitude of the internal voltage drop within the machine at a load current of 200 A is  (A) 1 V (B) 10 V (C) 100 V (D) 1000 V

asked May 17, 2018 in Alternator by Shimroz123
1 answer 43 views

For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is

asked Apr 30, 2018 in Electrical Engineering by Shimroz123
1 answer 14 views

A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is (A) 300 W (B) 150 W (C) 45 W (D) 20 W

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 25 views

If resistance is 20 Q. and inductance is 27 in a R-L series circuit, then time constant of this circuit will be?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 192 views

A 10 km long line has a characteristic impedance of 400 ohms. If line length is 100 km, the characteristic impedance is: (1) 4000 Ω (2) 400 Ω (3) 40 Ω (4) 4 Ω

asked May 28, 2018 in Electric Power Transmission by Shimroz123
1 answer 20 views

Why are shunt reactors connected at the receiving end of long transmission line system: (1) To increase the terminal voltage (2) To compensate voltage rise caused by capacitive charging at light load (3) To improve power factor (4) None of these

asked May 22, 2018 in Electric Power Transmission by Shimroz123
0 answers 31 views

Which of the following relations is true for long transmission line ? (a) VS = AVR – BIR (b) VS = BVR + AIR (c) VS = AVR + BIR (d) VS = BVR – AIR

asked May 26, 2018 in Electric Power Transmission by Shimroz123
0 answers 25 views

Which of the following is used for power factor improvement in transmission line ? (a) Three phase induction (b) An overexcited three phase synchronous motor running on no load (c) Three phase AC series motor (d) Choke

asked May 26, 2018 in Electric Power Transmission by Shimroz123
1 answer 384 views

The main consideration for operating transmission line at high voltage is (a) to increase efficiency only. (b) to reduce power loss only. (c) to increase power transmission capability only. (d) All of the above

asked May 26, 2018 in Electric Power Transmission by Shimroz123
1 answer 55 views

How many insulator disc used for 33 kV transmission voltage line?

asked Dec 5, 2017 in Electric Power Transmission by Quiz
1 answer 12 views

The standing wave ratio of a 75 Ω transmission line used to feed a 300 Ω resistive load will be _____.

asked May 29, 2018 in Electrical Engineering by Shimroz123
1 answer 12 views

A transmission line is terminated at its characteristic impedance. The reflection coefficient is  (a) 1 (b) –1 (c) 0 (d) ∞

asked May 16, 2018 in Network Analysis by Shimroz123
1 answer 17 views

A long overhead transmission line is terminated by its characteristic impedance. Under this operating condition, the ratio of the voltage to the current at different points along the line will?

asked Mar 27, 2018 in Power system by Shimroz123
1 answer 19 views

A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 106 views

If a 5-bus test system contains 6 transmission lines and one transformer, how many non-zero elements are there in the system Y-bus ? (A) 25 (B) 12 (C) 11 (D) 19

asked Apr 28, 2018 in Power system by Shimroz123
1 answer 25 views

A single-phase transformer has no-load loss of 64 W, as obtained from an open circuit test. When a short-circuit test is performed on it with 90% of the rated currents flowing in its both LV and HV windings, he measured loss is 81 W. The transformer has maximum efficiency when operated at  (A) 50.0% of the rated current (B) 64.0% of the rated current (C) 80.0% of the rated current (D) 88.8% of the rated current

asked May 17, 2018 in Transformer by Shimroz123
0 answers 67 views

In a network containing resistances and reactances the roots of the characteristic equation give for the circuit : (A) The forced response (B) The total response (C) The natural response (D) The damped response

asked Mar 31, 2018 in Electrical Engineering by Shimroz123
0 answers 308 views

Two generating stations G1 and G2 of ratings 10 MVA and 8 MVA respectively are linked by a line rated at 5 MVA, 0.1 Pu reactance. Each station has a reactance of 0.5 pu. If the base MVA is 10 MVA, short-circuit MVA of G1 is

asked May 24, 2018 in Power system by Shimroz123
1 answer 17 views

When an antenna of input resistance 73 ohm is connected to a 50-ohm line and if the losses are ignored then its efficiency will be nearly   (A) 0.19 (B) 0.81 (C) 0.97 (D) 1.19

asked May 17, 2018 in Electronics communication by Shimroz123
1 answer 123 views

A 50Ω transmission line is terminated in an impedance of 20-j50. What will be the reflection coefficient? A) 0.69 B) 1.69 C) 6.9 D) 16.9 

asked Jun 18, 2018 in Electrical Engineering by Shimroz123
1 answer 19 views

A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, j0.1 and j0.04 respectively. The neutral of the alternator is connected to ground through an inductive reactor of j0.05 p.u. The per unit positive-, ... The voltage of the alternator neutral with respect to ground during the fault is  (A) 513.8 V (B) 889.9 V (C) 1112.0 V (D) 642.2 V

asked May 25, 2018 in Power system by Shimroz123
1 answer 26 views

A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/69 kV rating. A 0.72 pu. load, evaluated on load side transformer ratings as base values , is supplied from the above system. For system base values of 10 MVA and 69 kV in load circuit, the value of the load (in per unit) in generator will be (A) 36 (B) 1.44 (C) 0.72 (D) 0.18

asked May 25, 2018 in Power system by Shimroz123
2 answers 53 views

A long transmission line has considerable ……………….. effect. A) series capacitance B) shunt capacitance C) series inductance D) shunt inductance

asked Jun 4, 2018 in Electric Power Transmission by Shimroz123
1 answer 46 views

A single-line-to-ground fault on a overhead transmission line creates (A) voltage sag (B) voltage swell (C) over voltage (D) voltage flicker 

asked Jun 4, 2018 in Electric Power Transmission by Shimroz123
0 answers 18 views

The power loss in a transmission line depends on (a) current in the line. (b) resistance of the line. (c) length of the line. (d) All of the above 

asked May 26, 2018 in Electric Power Transmission by Shimroz123
0 answers 21 views

A transmission line to be reciprocal, the condition is (a) A = D (b) AC – BD = 1 (c) AD – BC = 1 (d) AB – CD = 1  

asked May 25, 2018 in Electric Power Transmission by Shimroz123
0 answers 22 views

An overhead transmission line has a span of 260 m. The weight of the conductor is 0.68 kg/m. The maximum allowable tension in the line is 1550 kg. Maximum sag of the line should be (a) 5.8 m (b) 4.6 m (c) 2.7 m (d) 3.7 m 

asked May 25, 2018 in Electric Power Transmission by Shimroz123
1 answer 27 views

To increase power transfer capability of a long transmission line, we should:  (1) Increase line resistance (2) Increase transmission voltage (3) Decrease line reactance (4) Both (2) & (3)

asked May 22, 2018 in Electric Power Transmission by Shimroz123
1 answer 27 views

The inductance of a power transmission line increases with (A) decrease in line length. (B) increase in conductor diameter. (C) increase in spacing between phase conductors. (D) increase in load current carried by conductors.

asked May 13, 2018 in Electric Power Transmission by Shimroz123
1 answer 31 views

Stability of a transmission line can be increased by

asked May 8, 2018 in Electric Power Transmission by Shimroz123
1 answer 99 views

A transmission line has 1 P.0 impedance on a base of 11 KV, 100 MVA. On a base of 55 KV. it will have a P.0 impedance of

asked May 3, 2018 in Electric Power Transmission by Shimroz123
0 answers 101 views

For extra high voltage ac transmission lines, conductors used are (a) All aluminium (b) All steel (c) AAAC (d) ACSR

asked May 26, 2018 in Electric Power Transmission by Shimroz123
0 answers 21 views

A dc shunt motor runs at 500 r.p.m at 220 V. A resistance of 4.5 Ω is added in series with the armature for speed control. The armature resistance is 0.5 ohms. The current to stall the motor will be (1) 44 A (2) 50 A (3) 44.4 A (4) 60 A  

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
0 answers 50 views

A single phase transmission line and a telephone line are both symmetrically strung one below the other, in horizontal configurations, on a common tower, The shortest and longest distances between the phase and telephone conductors are 2.5 m and 3 m respectively. The voltage (volt/km) induced in the telephone circuit, due to 50 Hz current of 100 amps in the power circuit is (A) 4.81 (B) 3.56 (C) 2.29 (D) 1.27

asked May 25, 2018 in Power system by Shimroz123
0 answers 24 views

The sending and receiving end voltages of a three phase transmission line at 100 MW load are equal at 230 KV. The phase line impedance is j14 ohm. Calculate the maximum steady state power that can be transmitted over the line.  (A) 3778.5 MW (B) 2234.56 MW (C) 1784.19 MW (D) 512.37 MW

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 19 views

The main limitation for power handling capability of short length transmission lines and cables is (A) power factor (B) stability (C) thermal effect limit (D) conductor size

asked Apr 25, 2018 in Electrical Engineering by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,503 questions

7,101 answers

134 comments

3,090 users

...