Can you help by answering this question?

A single FSM can be converted to two smaller FSM. Justify.

33 views
in Electrical Engineering by
The characteristic equation of a simple servo system is s2+6s+25=0. Damping factor of the system is: A) 3.2 B) 2.4 C) 1.8 D) 2.9

Related questions

1 answer 23 views

The characteristic equation for a closed loop system with forward gain K is s4 + 4s3 + 8s2 + 6s + K = 0. The critical gain value Kc for stability should not exceed  (a) 3.25 (b) 9.75 (c) 13.0 (d) 23.3

asked May 15, 2018 in Control System by Shimroz123
1 answer 37 views

If the characteristics equation of a closed loop system is s2+2s+2=0, then the system is  (A) Over damped (B) Critically damped (C) Under damped (D) Undamped 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 13 views

For a 2nd order servo system, the damping ratio δ = 0.5456 and undamped natural frequency is ωn = 31.6 rad/sec. The percent overshoot is  (a) 7.07 (b) 10.2 (c) 14.10 (d) 21.21

asked May 15, 2018 in Control System by Shimroz123
0 answers 143 views

The system described by the characteristic equation S4 +2S3 +3S2 +4s+5=0 has  A) No roots have positive real part B) One root has positive real part C) Two roots have the positive real parts D) None of these

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
1 answer 17 views

A discrete time system is stable if all the roots of the characteristic equation. lie (a) Outside the circle of unit radius (b) Within the circle of unit radius (c) Outside the circle of radius equal to 3 -units (d) On the circle of infinite radius

asked Apr 23, 2018 in Control System by Shimroz123
1 answer 35 views

The corona loss in a 50 Hz system is 0.25 kW/ph/km. At a frequency of 60 Hz, the corona loss would be   (a) 0.30 kW/ph/km (b) 0.36 kW/ph/km (c) 028 kW/ph/km (d) 0.21 kW/ph/km

asked May 13, 2018 in Power system by Shimroz123
1 answer 19 views

Given a unity feedback system with G(s)=k/s (s+4), the value of k for damping ratio of 0.5 is

asked May 8, 2018 in Control System by Zeeshan
1 answer 17 views

The damping factor of a particular system is unity, the system response will be

asked Apr 26, 2018 in Control System by Shimroz123
0 answers 62 views

In a network containing resistances and reactances the roots of the characteristic equation give for the circuit : (A) The forced response (B) The total response (C) The natural response (D) The damped response

asked Mar 31, 2018 in Electrical Engineering by Shimroz123
0 answers 119 views

What is the order of the characteristic equation of an armature controlled DC motor?  (A) First order equation (B) Second order equation (C) Zero order equation (D) Third order equation 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 17 views

A diesel power station spends 0.25 kg/kWh fuel. If the calorific value is 10,000 kcal/kg then overall efficiency of the power station will be   (a) 25% (b) 30% (c) 34.4% (d) 100% 

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
0 answers 26 views

In the case of second order differential equation if the damping ratio is unity, then the poles are  A) Equal, positive and real B) Imaginary and complex conjugate C) Equal, negative and real D) None of the above

asked Apr 9, 2018 in High voltage engineering by Shimroz123
1 answer 24 views

A control system having unit damping factor will give  (1) Oscillatory response (2) Undamped response (3) Critically damped response (4) No response

asked May 1, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 15 views

The equation V·j = 0 is known as : (A) Poissons’s equation (B) Laplace equation (C) Continuity equation (D) Maxwell equation

asked Mar 31, 2018 in Electrical Engineering by Shimroz123
0 answers 14 views

An electromechanical closed –loop control system has the transfer function C(s)/R(s) = k/s (s2 + s +1) (s+ 4) +k. Which one of the following is correct?  (A) The system is stable for all positive values of k (B) The system is unstable for all values of k (C) The system is stable for values of k between zero and 3.36 (D) The system is stable for values of k between 1.6 and 2.45 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 43 views

For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is

asked Apr 30, 2018 in Electrical Engineering by Shimroz123
1 answer 83 views

The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 13 views

In a system, the damping coefficient is - 2. The system response will be (a) Undamped (b) Oscillations with decreasing magnitude (c) Oscillations with increasing magnitude (d) Critically damped

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
0 answers 31 views

An ammeter of 0-25 A range has a guaranteed accuracy of 1% of full scale reading. The current measured 5 A The limiting error is  A) 2% B) 2.5% C) 4% D) 5%

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
1 answer 7 views

For a system with derivative feedback, forward path transfer is G(s) = I / (s2 + s + 1) and feedback path transfer is H(s) = Ks. What is the value of K to obtain a critically-damped closed loop transient response.  (a) 0.5 (b) 0.707 (c) 1 (d) 1.414

asked May 15, 2018 in Control System by Shimroz123
1 answer 27 views

Two wattmeters are used to measure the power in a 3 -phase balanced system. What is the power factor of the load when one wattmeter reads twice the other ?  (a) 0 (b) 0.5 (c) 0.866 (d) 1

asked Apr 23, 2018 in Electrical Engineering by Zeeshan
0 answers 70 views

. If the peak transmitted power in a radar system is increased by a factor of 16, the maximum range will be increased by a factor of : (A) 2 (B) 4 (C) 8 (D) 16

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
1 answer 17 views

A simple phase transformer has a maximum efficiency of 90% at full load and unity power factor. Efficiency at half load at the same power factor is  (A) 86.7% (B) 88.26% (C) 88.9% (D) 87.8%

asked May 17, 2018 in Transformer by Shimroz123
0 answers 7 views

Calculate the resistance value in ohms for the following conductance values: (a) 0.002 S (b) 0.004 S (c) 0.00833 S (d) 0.25 S.

asked Jul 1 by Shimroz123
0 answers 28 views

A system function has a pole at s=0 and a zero at s= -1. The constant multiplier is unity. For an excitation cos(t), What is the steady-state response?  (A) √2sin(t+450) (B) √2sin(t-450) (C) sin(t-450) (D) Sin(t) 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 13 views

For a desirable transient response of a second order system, the damping ratio must be between (a) 0.4 and 0.8 (b) 0.8 and 1.0 (c) 0.3 and 0.5 (d) 0.2 and 0.4

asked May 25, 2018 in Control System by Shimroz123
0 answers 8 views

In a second order system the value of resonant peak will be unity when the damping ratio has a value of  A) Zero B) Unity C) 0.707 D) 0.414

asked Apr 9, 2018 in Control System by Shimroz123
0 answers 19 views

A three phase transmission line delivers a load of 5 MW at 0.8 power factor lagging. Resistance of each conductor is 0.5 ohm / km. Receiving end voltage is 33 kV. If the line loss is not to exceed 10%, determine the length of the line.  (A) 7 km (B) 27.9 km (C) 56.8 km (D) 13.9 km

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 88 views

A single phase 60 Hz generator supplies an inductive load of 4500kW at a power factor of 0.80 lagging by means of a 20 km long overhead transmission line. The line resistance and inductance are 0.0195 ohm and 0.60 mH per km. The voltage at the receiving end is required to be kept constant at 10.2 kV. Find the voltage regulation of the line.  (A) 12.59% (B) 16.34% (C) 32.68% (D) 41.15% 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 20 views

In a power generating station the Demand Factor and Load Factor are 0.5 and 0.2, respectively. If the connected load is 400 MW, the average demand is (A) 40 MW (B) 100 MW (C) 140 MW (D) 280 MW

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
0 answers 18 views

Which among the following is the equation for the number of independent loops for a network with n nodes and b branches?  (A) n-1 (B) b+n-1 (C) b-n+1 (D) b-n

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
2 answers 238 views

The equation of 50 Hz current sine wave having r.m.s. value of 60 A is?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 16 views

In the time response analysis of control system, Damping Ratio is given by - a) Actual damping / Critical damping b) Critical damping /Actual damping c) ( Sum of the Actual damping and critical damping) /Actual damping d)( Difference of the Actual damping and critical damping) / critical damping

asked Apr 14, 2018 in Instrumentation and control by Shimroz123
1 answer 16 views

A Doppler Radar operating at 15 GHz is viewing a target moving directly towards it at the speed of 25 m/s. The Doppler frequency shift

asked May 23, 2018 in Electrical Engineering by Shimroz123
1 answer 62 views

The corona loss of a 3-phase transmission line is 100 kW at 60 kV/phase and 25 kW at 50 kV/phase. The disruptive critical voltage is (A) 40 kV (B) 43.6 kV (C) 49.6 kV (D) 50 kV

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 49 views

Ratings on a capacitor are given 25 µF, 12 V. Also a plus sign is written near one of its terminals. The capacitor is: -  a) Mica capacitor b) Ceramic capacitor c) Electrolytic capacitor d) Paper capacitor

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 19 views

Power factor of the system is kept high?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 13 views

The gain margin of a system is 0 dB. It represents a   (a) Stable system (b) Unstable system (c) Marginally stable system (d) Conditionally stable system

asked May 13, 2018 in Control System by Shimroz123
1 answer 17 views

The convergence characteristic of the Newton—Raphson method for solving a load flow problem is (A) quadratic (B) linear (C) geometric (D) cubic 

asked Apr 23, 2018 in Electrical Engineering by Shimroz123
1 answer 14 views

If the conductive loop on the rotor of a simple two -pole, single-phase generator rotates at the rate of 400 rps. The frequency of the induced output voltage will be: A. 40 Hz B. 100 Hz C. 400 Hz D. indeterminable

asked Apr 12, 2018 in Electrical Engineering by Shimroz123
1 answer 18 views

The benefit of power factor correction in a power system is (A) lower power consumption (B) increased demand charge (C) reduced load carrying capabilities in existing lines (D) reduced voltage profile

asked Apr 28, 2018 in Power system by Shimroz123
0 answers 21 views

If the antenna diameter in a radar system is increased by a factor of 4, the maximum range will be increased by a factor of  (a) 2 (b) 4 (c) 8 (d) 16

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
1 answer 16 views

The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu, 0.866 pu (B) 0.866 pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 31 views

Explain energy conservation method in lighting system by using installation of separate transformer / servo stabilizer.

asked Sep 22, 2018 in Energy Conservation And Audit by Shimroz123
0 answers 21 views

A single phase fully controlled thyristor bridge ac -dc converter is operating at a firing angle of 25 degree and an overlap angle 10 degree with constant dc output current of 20A. The fundamental power factor (displacement factor) at input ac mains is : (A) 0.78 (B) 0.827 (C) 0.866 (0) 0.9

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
1 answer 34 views

If the feedback factor of an amplifier is 0.1 and its gain without feedback is 40, then its gain with feedback is (a) – 13.3 (b) 200 (c) 8 (d) 10 

asked May 25, 2018 in Amplifier by Shimroz123
1 answer 6 views

The swing equation for a synchronous machine is based on (A) relative motion between load angle and stator magnetic field (B) maximum power flow possible through a particular point (C) net torque and angular displacement (D) relation between excitation voltage and excitation current

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 29 views

What is the job of a servo in a transmission?

asked Mar 10, 2018 in Control System by Quiz
1 answer 16 views

An alternator is delivering rated current at rated voltage and 0.8 power-factor lagging. For delivering rated current at rated voltage and 0.8 poWer—factor leading, the required excitation will be:  (A) less  (B) more (C) more or less (D) the same

asked Apr 9, 2018 in Electrical Engineering by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units
...