27 views
in Diode by
A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω  

Your answer

Thanks for your contribution. Feel free to answer this question. Please avoid short answer. Your answer is most welcome. Be genuine.

Upload image or document:

Your name to display (optional):
Privacy: Your email address will only be used for sending these notifications.
Anti-spam verification:
Are you a robot ? (Y = Yes / N = No)
To avoid this verification in future, please log in or register.

1 Answer

0 votes
by

A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω  

Related questions

1 answer 70 views

what is the minimum voltage required to turn on a diode ?

asked Dec 28, 2017 in Electrical Engineering by Quiz
1 answer 37 views
1 answer 21 views

Minimum voltage regulation occurs when the power factor of the load is?

asked Mar 19, 2018 in Transformer by Shimroz123
2 answers 64 views

How can you identify a zener diode?

asked Mar 15, 2018 in Electronics Engineering by Quiz
1 answer 47 views

Can we use a zener diode as a rectifier?

asked Dec 9, 2017 in Power Electronics by Quiz
1 answer 14 views

State any two applications of zener diode.

asked Sep 5, 2018 by Shimroz123
1 answer 10 views

List specification of zener diode

asked Sep 5, 2018 by Shimroz123
1 answer 28 views
1 answer 93 views
1 answer 18 views

A diode in which the change in reverse bias voltage varies the capacitance is called as A) Varactor diode B) Switching diode C) Tunnel diode D) Zener-diode  

asked Jun 18, 2018 in Diode by Shimroz123
1 answer 33 views

An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

asked Jun 18, 2018 in Electronics Engineering by Shimroz123
1 answer 69 views

A single-phase voltage source square -wave inverter feeds pure inductive load. The waveform of the load current will be

asked Apr 29, 2018 in Power Electronics by Shimroz123
1 answer 27 views

A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

asked Apr 30, 2018 in Power system by Shimroz123
0 answers 11 views

A Zener diode has a break down voltage of 9V and maximum power dissipation of 360 mW. The maximum current the diode can handle is (a) 20 mA (b) 30 mA (c) 35 mA (d) 40 mA

asked May 25, 2018 in Diode by Shimroz123
1 answer 67 views

Define: 1) voltage ratio, 2) current ratio, 3) transformation ratio of transformer.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 41 views

A 3 -phase, fully controlled, converter is feeding power into a DC load at a constant current of 150 A, the rms value of the current flowing through each thyristor of the converter is

asked Apr 29, 2018 in Power Electronics by Shimroz123
1 answer 283 views

The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero

asked Apr 28, 2018 in Power system by Shimroz123
1 answer 25 views

In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 24 views

A network is said to be under resonance when the voltage and the current at the network input terminals are (A) in phase (B) out of phase (C) in phase quadrature (D) in phase, and have equal magnitudes

asked Apr 28, 2018 in Network Analysis by Shimroz123
1 answer 17 views

The internal resistances of an ideal current source, and an ideal voltage source are, respectively, (A) 0, ∞ (B) ∞, ∞ (C) ∞, 0 (D) 0,0

asked Apr 28, 2018 in Network Analysis by Shimroz123
0 answers 38 views

A balanced Delta connected load supplied with 440 V 50 Hz three phase AC supply has R=10 Ohm and L=0.6 mH in is each arm. Calculate line and phase current, active power.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 15 views

In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 61 views

Give the circuit analysis of current source inverter with resistive load. What are the main difference between voltage source inverter and current source inverter?

asked Feb 18, 2018 in Unit 4 by Quiz
1 answer 14 views

A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is (A) 300 W (B) 150 W (C) 45 W (D) 20 W

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
2 answers 50 views

Write the relation between phase and line current, phase and line voltage for Star connection.

asked Aug 11, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 30 views

Which of the following theorems enables a number of voltage (or current) source to be combined directly into a single voltage (or current) source. (1) compensation theorem (2) reciprocity theorem (3) superposition theorem (4) Millman's theorem

asked Apr 29, 2018 in Network Analysis by Shimroz123
1 answer 30 views

For a transformer, operating at constant load current, maximum efficiency will occur at?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 79 views

A 3-phase voltage source inverter operates in 180° conduction mode with a star connected resistive load. If input dc voltage is 100 V, then the peak to peak output line voltage is :

asked Apr 30, 2018 in Electrical Engineering by Shimroz123
1 answer 15 views

Negative voltage regulation is indicative that the load is?

asked Mar 19, 2018 in Transformer by Shimroz123
0 answers 45 views

For a balanced three phase star connected load for which line voltage is 230V and per phase resistance and reactance is 6 Ohm and 8 Ohm respectively. Calculate: 1) phase voltage 2) line current 3) power factor 4) total power absorbed

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 7 views

Explain lagging quantity and leading quantity, explain this concept with voltage and current waveform

asked Sep 7, 2018 by Shimroz123
1 answer 36 views

Step-down transformer converts high voltage and low current into:  (A) How voltage and high current (B) High voltage and low current (C) Low voltage and high current (D) None of the above

asked May 8, 2018 in Electrical Engineering by Shimroz123
1 answer 21 views

A network that consists of at least a voltage source or current source is called A) Active network B) Ideal network C) Sourced network D) Outsourced network

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
1 answer 19 views

Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

asked May 8, 2018 in Electrical Engineering by Zeeshan
1 answer 36 views

Which of the following circuit breakers has high reliability & minimum maintenance?  (A) Bulk oil type CB (B) Air blast CB (C) Vacuum CB (D) Sulphur hexafluoride CB 

asked May 8, 2018 in Switchgear And Protection by Shimroz123
1 answer 26 views

A current controlled voltage source is equivalent to :  (A) series voltage feed -back amplifier (B) shunt current feed -back amplifier (C) shunt voltage feed -back amplifier (D) series current feed -back amplifier

asked Apr 30, 2018 in Electrical Engineering by Shimroz123
1 answer 106 views

Why does increase in current mean a decrease in voltage?

asked Mar 10, 2018 in High voltage engineering by Quiz
1 answer 20 views

Electrical shock happens for voltage/current?

asked Oct 30, 2017 in Electrical Engineering by Niloy
1 answer 28 views

The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

asked Mar 20, 2018 in Synchronous machine by Shimroz123
1 answer 36 views

What are the disadvantages of the linear regulator? how are they overcome in the switching regulator? What is continuous and discontinuous mode switching regulator?

asked Feb 11, 2018 in Unit 2 by Quiz
1 answer 56 views

Why inductor current lags inductor voltage ?

asked May 24 by Shimroz123
0 answers 92 views

 When The dc converter in figure shown has a resistance load of R = 10 Ω and the input voltage is Vs 220 V the converter switch remains on, its voltage drop is Vo -2 V. The chopping frequency is fI K sW Vs If the duty cycle is 50%, determine: (a) the average output voltage V (b) the RMS output voltage Vo (c) the converter efficiency (d) the effective input resistance of the converter

asked Apr 26 by Hussein
2 answers 30 views

Explain with circuit diagram operation of zener diode as a voltage regulator.

asked Sep 2, 2018 by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,484 questions

7,081 answers

134 comments

3,088 users

...