45 views
in Basic electrical and electronics engineering by
For a balanced three phase star connected load for which line voltage is 230V and per phase resistance and reactance is 6 Ohm and 8 Ohm respectively.

Calculate: 1) phase voltage 2) line current 3) power factor 4) total power absorbed

Your answer

Thanks for your contribution. Feel free to answer this question. Please avoid short answer. Your answer is most welcome. Be genuine.

Upload image or document:

Your name to display (optional):
Privacy: Your email address will only be used for sending these notifications.
Anti-spam verification:
Are you a robot ? (Y = Yes / N = No)
To avoid this verification in future, please log in or register.

Related questions

0 answers 38 views

A balanced Delta connected load supplied with 440 V 50 Hz three phase AC supply has R=10 Ohm and L=0.6 mH in is each arm. Calculate line and phase current, active power.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
2 answers 50 views

Write the relation between phase and line current, phase and line voltage for Star connection.

asked Aug 11, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 45 views

A single phase transformer has resistance and reactance of 0.2 pu and 0.6 pu respectively. Its pu voltage regulation at 0.8 pf lagging would he

asked May 3, 2018 in Power system by Shimroz123
0 answers 50 views

What is line voltage and phase voltage? Draw balanced three phase star connected system. Show all the voltages and currents.

asked Aug 11, 2018 in Basic electrical and electronics engineering by Quiz
0 answers 13 views

 A single phase, 2000V alternator has armature resistance and reactance of 0.8 ohm and 4.94 ohm respectively. The voltage regulation of the alternator at 100A, 0.8 leading pf is (A) 7% (B) - 8.9% (C) - 6.3% (D) 0%

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
1 answer 44 views

In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

asked Mar 18, 2018 in Alternator by Shimroz123
1 answer 225 views

Total instantaneous power supplied by a 3-phase ac supply to a balanced R-L load is

asked Apr 28, 2018 in Electrical Engineering by Shimroz123
0 answers 15 views

A balanced three phase star connected load is supplied from a three phase 400V 50 Hz supply. The resistance for per phase is 10 Ohm. Find the value of phase current, line current, power factor and total power consumed.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 58 views
2 answers 52 views

If resistance is 8 Ohm and current is 16 ampere then what will be the voltage and power?

asked Oct 21, 2017 in Electrical Engineering by Quiz
1 answer 79 views

A 3-phase voltage source inverter operates in 180° conduction mode with a star connected resistive load. If input dc voltage is 100 V, then the peak to peak output line voltage is :

asked Apr 30, 2018 in Electrical Engineering by Shimroz123
4 answers 173 views

What is the voltage in 3 phase line?

asked Dec 22, 2017 in Fundamentals of electrical power systems by Quiz
1 answer 67 views

Define: 1) voltage ratio, 2) current ratio, 3) transformation ratio of transformer.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 14 views

A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is (A) 300 W (B) 150 W (C) 45 W (D) 20 W

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
0 answers 15 views

Total numbers of ascending runs in the sequence 4 6 7 2 9 1 2 8 9 3 0  (1) 3 (2) 5 (3) 7 (4) 9  

asked Apr 10, 2018 in Computer Engineering by Shimroz123
0 answers 19 views

A three phase transmission line delivers a load of 5 MW at 0.8 power factor lagging. Resistance of each conductor is 0.5 ohm / km. Receiving end voltage is 33 kV. If the line loss is not to exceed 10%, determine the length of the line.  (A) 7 km (B) 27.9 km (C) 56.8 km (D) 13.9 km

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 49 views

What is the difference between line and phase voltage?

asked Mar 10, 2018 in High voltage engineering by Quiz
1 answer 47 views

The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

asked Apr 25, 2018 in Instrumentation and control by Shimroz123
1 answer 17 views

A three-phase star -connected load is operating at a power factor angle ϕ  with ϕ being the angle between

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 26 views

Why the read of 3 phase voltage is 440?

asked Mar 10, 2018 in Advanced electrical power system by Quiz
1 answer 21 views

At a particular instant, the R-phase voltage of a balanced 3-phase system is + 30 V, and the Y-phase voltage is – 90 V. The voltage of B-phase at that instant is (A) + 120 V (B) – 120 V (C) – 60 V (D) + 60 V

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 446 views

A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

asked Apr 28, 2018 in Electrical Engineering by Shimroz123
1 answer 5 views

Define balanced and unbalanced load in three phase circuit.

asked Sep 6, 2018 by Shimroz123
0 answers 103 views

A balanced three phase Delta connected load consists of three resistances each of four ohm's connected to a 400 V 3 phase 50 Hz supply. Find 1) phase voltage, 2) phase current, 3) line current, 4) power consumed.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
0 answers 28 views

Draw the Delta connected three phase system showing all the voltages and currents. Write the power equation.

asked Aug 11, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 19 views

A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, j0.1 and j0.04 respectively. The neutral of the alternator is connected to ground through an inductive reactor of j0.05 p.u. The per unit positive-, ... The voltage of the alternator neutral with respect to ground during the fault is  (A) 513.8 V (B) 889.9 V (C) 1112.0 V (D) 642.2 V

asked May 25, 2018 in Power system by Shimroz123
1 answer 34 views

A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 488 views

Explain the principle of ON-OFF control and phase control of AC voltage controller with suitable circuit and waveforms.

asked Feb 14, 2018 in Unit 6 by Quiz
0 answers 107 views

Three materials X, Y and Z having relative permittivity 2.5, 3.0 and 4.0 respectively are used in a single core cable. The materials on inner most and outer most layer respectively should be (a) X and Y (b) Y and Z (c) X and Z (d) Z and X 

asked May 25, 2018 in Physics by Shimroz123
1 answer 24 views

What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
1 answer 7 views

Define balanced 3 phase load.

asked Sep 7, 2018 by Zeeshan
1 answer 5 views

As shown in the figure, 1 ohm resistance is connected across a source that has a load line v + i = 100. The current through the resistance is A) 25 A B) 50 A C) 100 A D) 200A

asked May 20, 2018 in Network Analysis by Shimroz123
1 answer 78 views

The power consumed in a circuit element will be least when the phase difference between the current and voltage is?

asked Mar 24, 2018 in Electrical Engineering by Shimroz123
1 answer 31 views

A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 28 views

The maximum possible power of a 3-phase synchronous motor with synchronous reactance 0.8 p.u. connected to a bus-bar of 1.0 p.u. and excitation adjusted to 1.2 p.u. is (A) 0.5 p.u. (B) 0.96 p.u. (C) 1.5 p.u. (D) 1.8 p.u.

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 80 views

The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

asked May 17, 2018 in Electrical Machine by Shimroz123
1 answer 27 views

A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω  

asked Jun 18, 2018 in Diode by Shimroz123
1 answer 31 views

A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is? (A) 90° (B) 60° (C) 30° (D) 0° 

asked Apr 23, 2018 in Electrical Engineering by Shimroz123
3 answers 137 views

Three resistors of 4 Ω, 6 Ω and 9 Ω are connected in parallel. Which resistor consumes the maximum power?  (A) 4 Ω (B) 6 Ω (C) 9 Ω (D) 17 Ω

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 11 views

The three non -inductive loads of 5 kW, 3 kW and 2 kW are connected in a star network between R, Y and B phases and neutral. The line voltage is 400 V. The current in the neutral wire is nearly (a) 11 A (b) 14 A (c) 17 A (d) 21 A

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ?

asked Apr 23, 2018 in Electrical Engineering by Zeeshan
1 answer 54 views

The product of apparent power and cosine of the phase angle between circuit voltage and current is?

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 15 views

With a neat sketch explain working of 1 phase dynamometer type power factor meter.

asked Sep 6, 2018 by Shimroz123
1 answer 33 views

A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the core losses are 1200 W. The air-gap power of the motor will be (A) 23.06 kW (B) 24.11 kW (C) 25.01 kW (D) 26.21 kW

asked May 17, 2018 in Electrical Machine by Shimroz123
1 answer 24 views

For 11kV line the inductance per km per phase will be of the order of:  (A) 1 H (B) 0.1 H (C) 1 mH (D) 0.1 mH

asked May 8, 2018 in Electric Power Transmission by Shimroz123
1 answer 18 views

For 11 kV line the capacitance per km per phase will be of the order of:  (A) 1 Farad (B) 0.1 Farad (C) 0.01 Farad (D) 0.01 microF

asked May 8, 2018 in Electric Power Transmission by Shimroz123
0 answers 15 views
1 answer 22 views

The kVA rating of Three-phase transformer with Voltage = 200V and Current = 100A will be :  (A) 34.64 kVA (B) 75 kVA (C) 20 kVA (D) None of the above

asked May 8, 2018 in Electrical Engineering by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,471 questions

7,069 answers

134 comments