Give purpose and location of i) Uninsulated overlap. ii) Insulated overlap. iii) Neutral section. iv) Section insulator.

Your answer

Thanks for your contribution. Feel free to answer this question. Please avoid short answer. Your answer is most welcome. Be genuine.

Upload image or document:

Your name to display (optional):
Privacy: Your email address will only be used for sending these notifications.
Anti-spam verification:
Are you a robot ? (Y = Yes / N = No)
To avoid this verification in future, please log in or register.

1 Answer

0 votes
by
Ans: i) Insulated overlap: To isolate for operation and maintenance of OHE if two lengths of OHE belong to two elementary sections. Located at feeding posts, sub sectioning posts and booster sections. 

ii) Un-insulated overlap: To rectify faults in one contact wire of two running in parallel wires without affecting power to OHE. Located at two adjacent sub-elementary sections. 

iii) Neutral section: Passing of pantograph under insulated overlap will cause short circuit between two phases, damaging OHE & pantograph. To avoid this bridging a neutral section is inserted between them. Located between two substations. 

iv) Section insulator: Section insulators are provided to insulate OHE of one elementary section from the OHE of another adjacent elementary section. Located at cross over from one track to other, from main line to siding.