39 views
in Electrical Machine by
what is a pony motor ?

1 Answer

0 votes
by
pony motor is a small induction motor

Related questions

0 answers 31 views
asked Nov 11, 2018 by Ganesh
1 answer 18 views

A pony motor is basically a?

asked Mar 18, 2018 in Synchronous machine by Shimroz123
0 answers 11 views

What is the RPM of a DC motor?

asked Mar 15, 2018 in Electrical Machine by Quiz
1 answer 30 views

What is the definition of induction motor?

asked Mar 17, 2018 in Electrical Machine by Shimroz
1 answer 71 views

What is the function of induction motor?

asked Mar 17, 2018 in Electrical Machine by Shimroz
0 answers 17 views

What is the principle of synchronous motor?

asked Mar 15, 2018 in Electrical Machine by Quiz
0 answers 23 views

What is the use of synchronous motor?

asked Mar 15, 2018 in Electrical Machine by Quiz
0 answers 17 views

What is the principle of AC motor?

asked Mar 15, 2018 in Electrical Machine by Quiz
1 answer 58 views

What is mean by plugging in three phase induction motor?

asked Mar 3, 2018 in Electrical Machine by Quiz
1 answer 20 views

what is separately excited motor ?

asked Aug 15, 2017 in Electrical Machine by Zeeshan
1 answer 29 views

AC motor

asked Aug 9, 2017 in Electrical Machine by Zeeshan
2 answers 109 views

what is the difference between synchronous and asynchronous motor?

asked Aug 6, 2017 in Electrical Machine by Zeeshan
1 answer 47 views

What will happen if you increase the current in the motor?

asked Mar 15, 2018 in Electrical Machine by Quiz
0 answers 9 views

What are the parts of AC motor?

asked Mar 15, 2018 in Electrical Machine by Quiz
2 answers 91 views

What are the speed control methods of dc motor?

asked Dec 16, 2017 in Electrical Machine by Quiz
1 answer 30 views

what are the types of dc motor?

asked Aug 8, 2017 in Electrical Machine by Zeeshan
0 answers 26 views

A 200 V dc motor takes a field current of 2 A to generate a back emf of 180 V. If the field winding resistance is 80 Ω, the resistance of the shunt field regulator is (A) 10 Ω (B) 20 Ω (C) 100 Ω (D) 180 Ω

asked Jun 4, 2018 in Electrical Machine by Shimroz123
1 answer 27 views

For a 1.8o, 2-phase bipolar stepper motor, the stepping rate is 100 steps/second. The rotational speed of the motor in rpm is  (A) 15 (B) 30 (C) 60 (D) 90

asked May 17, 2018 in Electrical Machine by Shimroz123
1 answer 22 views

The armature resistance of a permanent magnet dc motor is 0.8 Ohm. At no load, the motor draws 1.5 A from a supply voltage of 25 V and runs at 1500 rpm. The efficiency of the motor while it is operating on load at 1500 rpm drawing a current of 3.5 A from the same source will be  (A) 48.0% (B) 57.1% (C) 59.2% (D) 88.8%

asked May 17, 2018 in Electrical Machine by Shimroz123
1 answer 33 views

A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the core losses are 1200 W. The air-gap power of the motor will be (A) 23.06 kW (B) 24.11 kW (C) 25.01 kW (D) 26.21 kW

asked May 17, 2018 in Electrical Machine by Shimroz123
1 answer 22 views

In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high resistance winding. (C) Small current flows through the outer high resistance winding. (D) Large current flows through the inner low resistance winding.

asked May 8, 2018 in Electrical Machine by Shimroz123
1 answer 36 views

A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

asked May 3, 2018 in Electrical Machine by Shimroz123
1 answer 38 views

The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above

asked May 1, 2018 in Electrical Machine by Shimroz123
1 answer 19 views

Slip test is performed to determine :  (A) Slip in an induction motor  (B) Xd and Xq in a salient pole alternator  (C) Synchronous impedance in an alternator  (D) Positive and negative sequence impedances of an alternator

asked Apr 29, 2018 in Electrical Machine by Shimroz123
1 answer 21 views

Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be

asked Apr 29, 2018 in Electrical Machine by Shimroz123
1 answer 32 views

A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for

asked Apr 29, 2018 in Electrical Machine by Shimroz123
1 answer 28 views

The function of a brush and commutator arrangement in a dc motor is to  (1) produce unidirectional torque (2) produce unidirectional current in the armature (3) help in changing the direction of rotation of the armature (4) reduce sparking

asked Apr 29, 2018 in Electrical Machine by Shimroz123
1 answer 23 views

In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in the same direction (C) the flux increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 152 views

The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 29 views

An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is (A) 5.06 kW (B) 0.3 kW (C) 100 kW (D) 83.33 kW

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 21 views

In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is (A) 0.2 Ω (B) 0.3 Ω (C) 0.4 Ω (D) 0.5 Ω

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 30 views

A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

asked Apr 28, 2018 in Electrical Machine by Shimroz123
0 answers 39 views

The rotor winding of a three phase wound rotor induction motor is equipped with a three phase diode rectifier connected to the slip rings and rectifier output is connected with chopper drive. Compared to conventional rotor resistance control scheme, the chopper controlled method  A) Enhances the motor rating B) Maintains the motor rating as such C) Derates the motor D) None of the above 

asked Apr 9, 2018 in Electrical Machine by Zeeshan
1 answer 18 views

As there is no back e.m.f. at the instant of starting a D.C. motor, in order to prevent a heavy current from flowing though the armature circuit?

asked Mar 20, 2018 in Electrical Machine by Shimroz123
1 answer 14 views

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units
...