For the parallel operation of single phase transformers, it is necessary that they should have same polarity.

0 votes
by

Necessary conditions required to be satisfied in order to ensure successful parallel operation of single phase transformers: 

1. Only transformers having the same phase displacement between primary and secondary voltage can operate in parallel. The clock-hour which indicate the phase displacement is stamped on the transformer rating plate, e.g. Dyn11, Yd11, 2. Terminals with the same polarity on HV- and LV side shall be connected in parallel, 3. Transformers should have approximately the same voltage ratio, within +-0.05% 4. The short-circuit impedance voltage should be the same, within +-10%, 5. The power rating of the transformers should not deviate more than 1:3, 6. Tap changers should have tap position giving voltage ratios as close as possible. 7. The phase sequence must be followed strictly on HV and LV side connection.

Amazon Shopping

Welcome to Q&A site for electrical and electronics engineering discussion for diploma, B.E./B.Tech, M.E./M.Tech, & PhD study.
If you have a new question please ask in English.
If you want to help this community answer these questions.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase factor resistance load synchronous energy ac induction generator electric series frequency capacitor use speed between electrical meter line type mosfet control transmission difference magnetic plant high single instrument bjt source advantages function diode machine unit winding torque amplifier define supply thyristor motors arduino field shunt maximum relay armature problem electricity time parallel on transformers types coil diagram state flow value material three starting and direction theorem method emf operating digital microprocessor test instruments efficiency ratio loss measure operation connected low applications wave effect single-phase working losses different network wattmeter temperature measuring constant signal controlled breaker device full compare drive wire resistivity logic materials machines inductance switch flux disadvantages converter transistor gain protection scr angle force core measurement number free principle rc generators law negative bridge friction open pole conductor conservation steam iron loop resistors hysteresis short computer using lines secondary station battery rectifier inverter linear relays nuclear regulation circuits design analog work rotor electronics gate forces diesel damping rlc connection factors capacitors minimum insulation basic moving running reactance systems air fault range direct main stability quality starter igbt eddy ideal ammeter rl 3-phase plants arc induced thermal error fuzzy biasing dielectric pressure balanced superposition errors rotation characteristics feedback measured electronic start alternator off back curve over solar three-phase tariff locomotive peak bias zener capacitance commutator surge rating universal potentiometer permanent mechanical copper self transducer capacity electrons memory adc excitation inductive transfer explain fuse pure harmonics application inductor internal pmmc average reaction welding resonance traction breakers designed electromagnetic si generation brushes density switching shaded rate impedance distribution methods star oscillator reluctance semiconductor simplification algebra 8085 boolean weston dynamometer insulating strength installation permeability definition fuel heating earth units neutral rms rated engineering conductors coefficient controller usually reverse excited analysis change body components
...