Primary winding of a transformer could either be a low voltage or high voltage winding.

Related questions

1 answer 20 views

In a transformer the resistance between its primary and secondary should be?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 25 views

A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

asked May 8, 2018 in Electrical Engineering by Shimroz123
0 answers 25 views
1 answer 14 views

Compare primary and secondary instruments.

asked Sep 6, 2018 by Shimroz123
1 answer 131 views

Primary and Backup Protection

asked Aug 9, 2017 in Switchgear And Protection by Zeeshan
1 answer 29 views

The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be (A) 3.6 V. (B) 2.5 V. (C) 3.0 V. (D) 6.0 V.

asked May 22, 2018 in Transformer by Shimroz123
1 answer 37 views

 An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

asked Jun 18, 2018 in Electronics Engineering by Shimroz123
1 answer 13 views

What will happen if the primary of a transformer is connected to D.C. supply?  (A) Transformer will operate with low efficiency (B) Transformer will operate with high efficiency (C) No effect (D) Transformer may start to smoke and burn 

asked May 8, 2018 in Electrical Engineering by Shimroz123
1 answer 28 views

A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

asked May 8, 2018 in Electrical Machine by Shimroz123
1 answer 36 views

A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

asked May 3, 2018 in Electrical Machine by Shimroz123
1 answer 31 views

Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

asked Apr 29, 2018 in Electrical Machine by Shimroz123
1 answer 30 views

The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

asked Mar 20, 2018 in Induction Machine by Shimroz123
1 answer 41 views

A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V

asked Apr 28, 2018 in Electrical Engineering by Shimroz123
1 answer 10 views
1 answer 31 views

When secondary of a current transformer is open-circuited its iron core will be?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 26 views

During open circuit test of a transformer?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 13 views

The size of a transformer core will depend on?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 15 views

In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 23 views

The secondary of a current transformer is always short-circuited under operating conditions because it?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 13 views

A good voltage regulation of a transformer means?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 16 views

The efficiency of a transformer, under heavy loads, is comparatively low because?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 20 views

The voltage transformation ratio of a transformer is equal to the ratio of?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 25 views

In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of?

asked Mar 19, 2018 in Transformer by Shimroz123
1 answer 20 views

The path of magnetic flux in a transformer should have?

asked Mar 19, 2018 in Transformer by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,483 questions

7,081 answers

134 comments

3,088 users

...