Can you help by answering this question?

A controller essentially is a/an

15 views
in DC generator by

The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

1 Answer

0 votes
by

The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Related questions

1 answer 55 views

A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly?

asked Mar 21, 2018 in DC generator by Shimroz123
1 answer 15 views

A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

asked May 8, 2018 in Electrical Machine by Shimroz123
1 answer 21 views

Which of the following quantity maintains the same direction whether a D.C. machine runs as a generator or as a motor a. Induced e.m.f. b. Armature Current c. Field Current d. Supply Current  

asked Sep 1, 2018 by Shimroz123
1 answer 36 views

A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

asked May 3, 2018 in Electrical Machine by Shimroz123
1 answer 15 views

The induced e.m.f. in the armature conductors of a d.c. motor is?

asked Mar 26, 2018 in DC motor by Shimroz123
1 answer 30 views

A 220 V dc machine has an armature resistance o f 1-ohm. If the full load current is 20A, the difference in the induced voltage when the machine is running as a motor, and as a generator is

asked Apr 1, 2018 in Electrical Engineering by Shimroz123
1 answer 17 views

For a D.C. generator when the number of poles and the number of armature conductors is fixed, then which winding will give the higher e.m.f. ?

asked Mar 20, 2018 in DC generator by Shimroz123
1 answer 25 views

According to Fleming's right-hand rule for finding the direction of induced e.m.f., when middle finger points in the direction of induced e.m.f., forefinger will point in the direction of?

asked Mar 20, 2018 in DC generator by Shimroz123
0 answers 21 views

A dc shunt motor runs at 500 r.p.m at 220 V. A resistance of 4.5 Ω is added in series with the armature for speed control. The armature resistance is 0.5 ohms. The current to stall the motor will be (1) 44 A (2) 50 A (3) 44.4 A (4) 60 A  

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
0 answers 16 views

The voltage regulation of an alternator having 0.75 leading p.f. load, no-load induced e.m.f. of 2400V and rated terminal voltage of 3000V is —————————————  A) 20% B) —20% C) 150 D) -26.7

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
1 answer 18 views

The e.m.f. induced in the primary of a transformer:  (A) is in phase with the flux (B) lags behind the flux by 90 degree (C) leads the flux by 90 degree (D) is in phase opposition to that of flux

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
1 answer 23 views

Five cells, each with an e.m.f. of 2V and internal resistance of 0.5Ω are connected in series. The resulting battery will have

asked May 14, 2018 in Electrical Engineering by Shimroz123
1 answer 22 views

The armature resistance of a permanent magnet dc motor is 0.8 Ohm. At no load, the motor draws 1.5 A from a supply voltage of 25 V and runs at 1500 rpm. The efficiency of the motor while it is operating on load at 1500 rpm drawing a current of 3.5 A from the same source will be  (A) 48.0% (B) 57.1% (C) 59.2% (D) 88.8%

asked May 17, 2018 in Electrical Machine by Shimroz123
1 answer 6 views

These self inductance of a circuit is defined as twice the work done against the induced e.m.f. on establishing unit current in the coil. If the current to be established in the coil is doubled, the work done against the induced e.m.f. will be  1. Doubled  2. Halved  3. four times  4. Quarter times 

asked May 13, 2018 in Electrical Engineering by Shimroz123
1 answer 20 views

 If shunt generator delivers 100 A at 200 V, and the resistance of the shunt field and armature are 100 ohm and 0.01 ohm respectively, the generated e.m.f. will be : -  a) 212 V b) 205 V c) 210 V d) 201.02 V

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

The armature reaction in a synchronous generator supplying leading power factor load is (A) magnetizing (B) demagnetizing (C) demagnetizing and cross-magnetizing (D) magnetizing and cross-magnetizing

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 16 views

A 35 V dc supply is connected across a resistance of 600 ohm in series with an unknown resistance R. A voltmeter having a resistance of 1.2 kOhm is connected across 600 ohm resistances and reads 5 V. The value of resistance R shall be:

asked May 22, 2018 in Electrical Engineering by Shimroz123
1 answer 33 views

A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

asked May 8, 2018 in Electrical Machine by Shimroz123
1 answer 2 views

State the use of shunt and series resistance used in extension of meter.

asked Sep 6, 2018 by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units
...