8 views
in Electrical Measurements and Instrumentation by

Your answer

Thanks for your contribution. Feel free to answer this question. Please avoid short answer. Your answer is most welcome. Be genuine.

Upload image or document:

Your name to display (optional):
Privacy: Your email address will only be used for sending these notifications.
Anti-spam verification:
Are you a robot ? (Y = Yes / N = No)
To avoid this verification in future, please log in or register.

1 Answer

0 votes
by

An induction meter can handle current up to 100 A.

Related questions

1 answer 37 views

An induction type energy meter is found to run fast. Correction for this error can be made by  (A) Over-load compensation. (B) Voltage compensation. (C) Moving the brake magnet away from the centre of the disc. (D) Moving the brake magnet towards the centre of the disc.

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
3 answers 91 views

What type of meter is used to measure current?

asked Mar 10, 2018 in Electrical Measurements and Instrumentation by Quiz
1 answer 10 views

State the function and shape of following parts used in induction type energy meter: i) Series magnet ii) Shunt magnet iii) Al disc iv) Brake magnet

asked Sep 6, 2018 by Shimroz123
1 answer 18 views

Draw a neat sketch of 1-ph induction type energy meter and write operating principle of it. 

asked Sep 6, 2018 by Shimroz123
1 answer 15 views

List any four errors in induction type energy meter. Give method of compensation for each.

asked Sep 5, 2018 by Shimroz123
1 answer 22 views

In the induction type directional over current relay, when a short-circuit occurs in the circuit (A) power flows in reverse direction (B) power flows in normal direction (C) directional power element does not operate (D) over current element is not energized

asked Apr 28, 2018 in Switchgear And Protection by Shimroz123
1 answer 15 views

Why does induction motor have high starting current?

asked Mar 15, 2018 in Electrical Engineering by Quiz
1 answer 18 views

A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

asked Apr 28, 2018 in Power Electronic Controlled Drives by Shimroz123
1 answer 44 views

The meter which does not have any component in it to provide control torque is (A) Electrodynamometer for current measurement (B) Electrodynamometer for voltage measurement (C) Electrodynamometer for power measurement. (D) Electrodynamometer for power factor measurement.

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 41 views

How can a magnetic field be used to generate an electric current?

asked Mar 10, 2018 in Engineering electromagnetic by Quiz
1 answer 29 views

The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

asked Apr 25, 2018 in Instrumentation and control by Shimroz123
1 answer 56 views
1 answer 27 views

A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

asked Apr 29, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 19 views

A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 21 views

A change of 4% in the supply voltage to an induction motor will produce a change of approximately

asked May 8, 2018 in Electrical Machine by Shimroz123
1 answer 41 views

In an induction motor if the flux density is reduced to one-half, of its normal value then the torque will  (1) reduce to one-half (2) reduce to one-fourth (3) remain unchanged (4) increase four times

asked May 1, 2018 in Electrical Machine by Shimroz123
1 answer 27 views

A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

asked Mar 20, 2018 in Synchronous machine by Shimroz123
0 answers 13 views

What is an RF Power Meter?

asked Mar 10, 2018 in Power quality by Quiz
0 answers 19 views

What does an electric meter measure?

asked Mar 10, 2018 in Power quality by Quiz
1 answer 29 views

Explain the “mitigation of power theft” and “faulty meter replacement” for energy conservation techniques to reduce commercial losses. 

asked Sep 22, 2018 in Energy Conservation And Audit by Shimroz123
1 answer 29 views

how can we reverse the direction of rotation of three phase induction motor ?

asked Oct 4, 2017 in Electrical Engineering by Quiz
1 answer 29 views

An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is (A) 5.06 kW (B) 0.3 kW (C) 100 kW (D) 83.33 kW

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 21 views

In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is (A) 0.2 Ω (B) 0.3 Ω (C) 0.4 Ω (D) 0.5 Ω

asked Apr 28, 2018 in Electrical Machine by Shimroz123
0 answers 33 views

Why starter is required for starting an induction motor?

asked Mar 15, 2018 in Electrical Engineering by Quiz
2 answers 59 views

The synchronous speed of an 8 pole induction motor supplied power from a 50 Hz source will be ?

asked Dec 31, 2017 in Electrical Engineering by Quiz
1 answer 22 views

The r.m.s. value of a sinusoidal A.C. current is equal to its value at an angle of______degrees.

asked Mar 24, 2018 in Electrical Engineering by Shimroz123
1 answer 13 views

List out any four effects of electric current used in measuring instruments & write name of meter working on it.

asked Sep 6, 2018 by Shimroz123
1 answer 40 views

The rotor impedance of a slip ring induction motor is (0.1 + j0.6)Ohm/ ph . The resistance/ph to be inserted into rotor to get maximum torque at starting should be

asked May 3, 2018 in Electrical machine design by Shimroz123
1 answer 22 views

Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be

asked Apr 29, 2018 in Electrical Machine by Shimroz123
1 answer 23 views

In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in the same direction (C) the flux increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

asked Apr 28, 2018 in Electrical Machine by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,530 questions

7,129 answers

135 comments

3,090 users

...