in Digital Instrumentation by
Standard Commands for Programmable Instruments (SCPI)

Amazon Shopping

Please log in or register to answer this question.

2 Answers

+1 vote
by
 
Best answer

Standard Commands for Programmable Instruments (SCPI)

image

image

image

image

image

0 votes
by

Standard Commands for Programmable Instruments (SCPI)

SCPI stands for Standard Commands for Programmable Instruments it is often pronounced as Skippy.

SCPI is a instrument language that control the functions of instrument in standardized form define by IEEE 488.2.

It is the standardized command between computer and instrument.

IEEE 488.2 defines how to send command to instrument and how to respond to computer.

Two similar instrument compatible with IEEE 488.2 each using completely different instruction.

SCPI organized in three sections one is syntax and style second is command reference third is data interchange format.


 Lets discuss about each block

Measurement function : transforms signal into preprocessed form.

Signal routing : connects the signal to internal function of instrument.

Input : filtering, bias and attenuation and condition the input signal.

Sense : control range, resolution and convert signal data into internal data that can be managed by user.

Calculate : calculation function uses variables such as converting units and rise time, fall time and frequency.

Format : transform instrument data to compatible form.

Signal generation : converts internal data.

Signal routing : it is connected to output which connects to outside world.

Output : filtering, bias and attenuation and condition the signal after signal generation.

Source : amplitude modulation, power, current, voltage and frequency from these parameter and internal data it generates signals.

Calculate : calculate data and convert application data and change units and domains.

Format : transform data to form compatible with internal function of instrument.

Trigger : it is for triggering.

Memory : memory is for storing data in instrument.

Display : for presentation.


Amazon Shopping

Welcome to Q&A site for electrical and electronics engineering discussion for diploma, B.E./B.Tech, M.E./M.Tech, & PhD study.
If you have a new question please ask in English.
If you want to help this community answer these questions.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase factor resistance load synchronous energy ac induction generator electric series frequency capacitor use speed between electrical meter line type mosfet control transmission difference magnetic plant high single instrument bjt source advantages function diode machine unit winding torque amplifier define supply thyristor motors arduino field shunt maximum relay armature problem electricity time parallel on transformers types coil diagram state flow value material and three starting direction theorem method emf operating digital microprocessor test instruments efficiency ratio loss measure operation connected low applications wave effect single-phase working losses different network wattmeter temperature measuring constant signal controlled breaker device full compare drive wire resistivity logic materials machines inductance switch flux disadvantages converter transistor gain protection scr angle force core measurement number free principle rc generators law negative bridge friction open circuits pole conductor conservation steam iron loop resistors hysteresis reactance short computer using lines secondary station battery rectifier inverter linear relays nuclear regulation design analog work rotor electronics gate forces diesel damping rlc connection factors capacitors minimum insulation basic moving running systems air fault range direct main stability quality starter igbt eddy ideal ammeter rl 3-phase plants arc induced thermal error fuzzy biasing dielectric pressure balanced superposition errors rotation characteristics feedback measured electronic inductive start alternator off back curve over solar three-phase tariff locomotive peak bias zener capacitance commutator surge rating universal potentiometer permanent mechanical copper self transducer capacity electrons memory adc excitation transfer explain fuse pure harmonics application inductor internal pmmc average reaction welding resonance traction breakers designed electromagnetic si generation brushes density switching shaded rate impedance distribution methods star oscillator reluctance semiconductor simplification algebra 8085 boolean weston dynamometer insulating strength installation permeability definition fuel heating earth units neutral rms rated engineering conductors coefficient controller usually reverse excited analysis change body components
...