Can you help by answering this question?

Thevenin's and Norton's Theorems 7

6 views
in Electrical Measurements and Instrumentation by

1 Answer

0 votes
by

For high accuracy the meter has Hand drawn scale.

Related questions

1 answer 87 views

A 0-10 A ammeter has a guaranteed accuracy of 1% of full scale deflection, the limiting error while reading 2.5 A will be (a) 1% (b) 2% (c) 4% (d) None of these 

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 19 views

A 0 to 300V voltmeter has a guaranteed accuracy of 1% of full scale reading. The voltage measured by the instrument is 83V. The percentage limiting error is

asked Mar 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 26 views

A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

asked Apr 29, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 12 views

Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

asked Jun 17, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 23 views

 In the case of an instrument reading of 8.3 V with a 0 to 150 voltmeter having a guaranteed accuracy of 1% full scale reading, the percentage limiting error is   (A) 1.810% (B) 0.181% (C)12.45% (D) 0.0018%

asked May 17, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 49 views

Which of the following ADC has highest accuracy ?  (a) Successive approximation type (b) Flash or parallel type (c) Single slope integration type (d) Dual slope integration type

asked Apr 23, 2018 in Electrical Engineering by Shimroz123
0 answers 31 views

An ammeter of 0-25 A range has a guaranteed accuracy of 1% of full scale reading. The current measured 5 A The limiting error is  A) 2% B) 2.5% C) 4% D) 5%

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
1 answer 53 views
1 answer 37 views

An induction type energy meter is found to run fast. Correction for this error can be made by  (A) Over-load compensation. (B) Voltage compensation. (C) Moving the brake magnet away from the centre of the disc. (D) Moving the brake magnet towards the centre of the disc.

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 33 views

A 150 V moving iron voltmeter of accuracy class 1.0 reads 75 V when used in a circuit under a standard conditions. The maximum possible percentage error in the reading is:

asked Mar 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 16 views

A compensated wattmeter has its reading corrected for error due to (a) Frequency (b) Friction (c) Power consumed in current coil (d) Power consumed in pressure coil

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 19 views

The full scale range of PMMC voltmeter is 100 V and its sensitivity is 1000 Ω/V. If the meter reads 50 V, the current through the voltmeter is (A) 0.05 mA (B) 0.5 mA (C) 5 mA (D) 50 mA 

asked Jun 4, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 70 views

The power in a 3-phase load is measured by two watt meters. If one watt meter reads zero, then the load power factor is (A) Zero (B) 0.5 (C ) 0.866 (D) unity 

asked Jun 4, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 23 views

The constant of a given energy meter is 500 revolution/kWh. At the test 4.4 kW full load, meter completes 50 revolutions in 86 seconds. The percentage error of the meter is (a) –4.86% (b) 4.86% (c) 2.0% (d) 3.0%

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 18 views

In a particular meter, the deflecting torque is directly proportional to the current flowing through it, the type of meter is (a) moving coil (b) moving iron (c) induction (d) electro-static  

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 8 views

The sensitivity of a voltmeter using 0-5 mA meter movement is (a) 200 Ω/V (b) 150 Ω/V (c) 100 Ω/V (d) 50 Ω/V 

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 11 views

The disc of domestic supply energy meter is made of which material ? (a) Zinc (b) Copper (c) Aluminium (d) Silver 

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 25 views

A d.c. ampere-hour meter is rated at 5A, 250 V. The declared constant is 5 A sec/revolution. The constant in revolution/kwh will be (a) 2880 (b) 2680 (c) 2480 (d) 2280

asked May 25, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 23 views

A reading of 120 is obtained when a standard inductor was connected in the circuit of a Q-meter and the variable capacitor is adjusted to a value of 300 pF. A lossless capacitor of unknown value Cx is then connected in parallel with the variable capacitor and the same reading was obtained when the variable capacitor is readjusted to a value of 200 pF. The value of Cx in pF is  A) 100 B) 200 C) 300 D) 500

asked May 20, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 44 views

The meter which does not have any component in it to provide control torque is (A) Electrodynamometer for current measurement (B) Electrodynamometer for voltage measurement (C) Electrodynamometer for power measurement. (D) Electrodynamometer for power factor measurement.

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 19 views

A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 19 views

Identify the instrument that does not exist (A) Dynamo-meter type ammeter (B) Dynamo-meter type wattmeter (C) Moving-iron voltmeter (D) Moving-iron wattmeter

asked Apr 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 58 views

An energy meter has a constant of 600 rev/kWh. If the meter makes 10 revolutions in 20 s, what is the load in kW?  (A) 0.75 kW (B) 1.5 kW (C) 3 kW (D) 6 kW 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 49 views

A high-pass filter has a resistance R = 2 kΩ The lowest input frequency to be passed is 7.5 kHz. The value of suitable coupling capacitor must be: A) 0.001 pico Farad B) 0.01 pico Farad C) 0.1 pico Farad D) 1 pico Farad

asked Jun 4, 2018 in Electrical Engineering by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units
...