Can you help by answering this question?

Explain the significance of over modulation.

21 views
in Electrical Measurements and Instrumentation by
 The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. If this meter is to have full deflection at 5A, what is the value of the shunt resistance to be used?

Your answer

Thanks for your contribution. Feel free to answer this question. Please avoid short answer. Your answer is most welcome. Be genuine.

Upload image or document:

Your name to display (optional):
Privacy: Your email address will only be used for sending these notifications.
Anti-spam verification:
Are you a robot ? (Y = Yes / N = No)
To avoid this verification in future, please log in or register.

1 Answer

0 votes
by

 The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. If this meter is to have full deflection at 5A, 1/49.99 ohms is the value of the shunt resistance to be used.

Related questions

1 answer 23 views

The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. This is to have full deflection when 100V is measured. What is the value of series resistor to be used?

asked Mar 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 13 views

An ammeter has a current change of 0—5A and its internal resistance is 0.2 ohm. In order to Change the range to 0-25 A, wear need to add a resistance of  A) 0.8 ohm in series with the meter B) 1.0 ohm in series with the meter C) 0.04 ohm in parallel with the meter D) 0.05 ohm in parallel with the meter

asked May 20, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 21 views

A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

asked May 22, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 92 views

A 0-10 A ammeter has a guaranteed accuracy of 1% of full scale deflection, the limiting error while reading 2.5 A will be (a) 1% (b) 2% (c) 4% (d) None of these 

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 18 views

A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

asked Apr 28, 2018 in Power Electronic Controlled Drives by Shimroz123
0 answers 31 views

An ammeter of 0-25 A range has a guaranteed accuracy of 1% of full scale reading. The current measured 5 A The limiting error is  A) 2% B) 2.5% C) 4% D) 5%

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
1 answer 25 views

A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect • 10 W resistance in series • 10 W resistance in parallel • 10/1999 W resistance in series • 10/1999 W resistance in parallel

asked May 13, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 19 views

The full scale range of PMMC voltmeter is 100 V and its sensitivity is 1000 Ω/V. If the meter reads 50 V, the current through the voltmeter is (A) 0.05 mA (B) 0.5 mA (C) 5 mA (D) 50 mA 

asked Jun 4, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 21 views

DC ammeter has a resistance of 0.1 Ω and its current range is 0-100 A. If the range is to be extended to 0-300 A, what shunt resistance need to be connected?  A) 0.025 Ω B) 0.05 Ω C) 0.015 Ω D) 0.03 Ω

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
0 answers 381 views

Internal resistance of a micro-ammeter is 500 ohm. Shunt resistance required to increase its range from 0-100 µA to 0-10 A will be approximately (a) 0.05 Ω (b) 0.005 Ω (c) 0.5 Ω (d) 5.0 Ω

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 62 views

The capacitance of 0-1000V electrostatic voltmeter increases from 36-42 pF from zero to full scale deflection. It is required to extend the range of voltmeter to 10000 V by using an external series capacitor. What should be the value of series capacitor?  (A) 0.8 pF (B) 1.00 pF (C) 6.644 pF (D) 4.667 pF 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 23 views

The emf induced in a coil is 1 volt when current in it changes from 0 to 100 mA in time 10mS. Its inductance (in mH) value is  A) 10 B) 50 C) 100 D) 1000

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
0 answers 14 views

One 200 KVA transformer has an iron loss of 1 KW and full load Cu loss of 2 KW. Its load KVA corresponding to maximum efficiency is:  (A) 100 KVA (B) 141.4 KVA (C) 50 KVA (D) 200 KVA 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 11 views

Series resistance required to read 0-250 V with a moving coil instrument of internal resistance 2 ohm and full scale deflection of 50 mA is (a) 49998 Ω (b) 4998 Ω (c) 498 Ω (d) 49.8 Ω

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 18 views

 A 0 -10 mAPMMC ammeter reads 5 mA in a circuit; its bottom control spring snaps out suddenly the meter will now read:- a) 5 mA b) 10 mA c) 2.5 mA d). 0

asked Apr 14, 2018 in Instrumentation and control by Shimroz123
1 answer 14 views

A d.c. source has an open circuit voltage of 30 V and an internal resistance of 1.5 Ohm. A resistive load is connected to the source. Maximum power dissipated in the load is (A) 300 W (B) 150 W (C) 45 W (D) 20 W

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 53 views

A digital voltmeter has a read-out range from 0 to 9999 counts. When full scale reading is 9.999 V, the resolution of the instrument will be (a) 100 mV (b) 99 mV (c) 9 mV (d) 1 mV 

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 30 views

A 220 V dc machine has an armature resistance o f 1-ohm. If the full load current is 20A, the difference in the induced voltage when the machine is running as a motor, and as a generator is

asked Apr 1, 2018 in Electrical Engineering by Shimroz123
1 answer 56 views

When there is 12 mA of current through a 1.2 k ohms resistor, the voltage across the resistor is? A.14.4 V B.1.4 V C.100 V D.10 V

asked May 15, 2018 in Basic concepts by Shimroz123
1 answer 43 views

A dc voltmeter has a sensitivity of 1000 Ohm/V. When it measures half full scale in 100 V range, the current through the voltmeter is

asked Apr 23, 2018 in Electrical Engineering by Shimroz123
1 answer 18 views

The internal resistances of an ideal current source, and an ideal voltage source are, respectively, (A) 0, ∞ (B) ∞, ∞ (C) ∞, 0 (D) 0,0

asked Apr 28, 2018 in Network Analysis by Shimroz123
0 answers 24 views

A single phase 230 V/ 150 V , 1 kVA, 50 Hz transformer is supplied by 230 V AC supply. Find the full load primary and secondary current. 

asked Sep 1, 2018 by Quiz
1 answer 23 views

A 10A DC Ammeter has a resistance of 0.1 Ω is to be extended to 50 A, the required shunt wire is A) Manganin wire of 20 m Ω B) Constantan wire of 20 m Ω C) Manganin wire of 25 m Ω D) Constantan wire of 25 m Ω

asked Jun 4, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 30 views

For an ADC, full scale output voltage is about 10 V.For a resolution of about 9.78mV, number of bits required is  A) 6 B) 8 C) 10 D) 12

asked Apr 9, 2018 in Electronics Engineering by Shimroz123
1 answer 19 views

A 0 to 300V voltmeter has a guaranteed accuracy of 1% of full scale reading. The voltage measured by the instrument is 83V. The percentage limiting error is

asked Mar 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 34 views

If the feedback factor of an amplifier is 0.1 and its gain without feedback is 40, then its gain with feedback is (a) – 13.3 (b) 200 (c) 8 (d) 10 

asked May 25, 2018 in Amplifier by Shimroz123
0 answers 27 views

The period of time between an allocation and its subsequent disposal is called  (1) scope (2) lifetime (3) longevity (4) dynamic binding

asked Apr 10, 2018 in Computer Engineering by Shimroz123
0 answers 32 views

What will happen if a voltmeter is connected like an ammeter in series of the load ? (a) The meter will burn out. (b) The measurement will be too high. (c) The same current will flow as would have been with ammeter in circuit. (d) There will be almost no current in the circuit. 

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 32 views

The r.m.s. value of a half-wave rectified alternating current is 10 A. Its value for full-wave rectification will be  

asked May 25, 2018 in Electrical Engineering by Shimroz123
1 answer 78 views

 If the base current of a BJT is 250 µA and emitter current is 15 mA, then the common base current gain will be A) 0.98 B) 0.41 C) 59 D) 55  

asked Jun 18, 2018 in Bipolar Junction Transistor by Shimroz123
0 answers 13 views

An array is not full, The time complexity of Insertion in an array at a specific position is  (1) O(nlogn) (2) O(1) (3) O(n) (4) O(logn)  

asked Apr 10, 2018 in Computer Engineering by Shimroz123
1 answer 113 views

The time/div and voltage/div axes of an oscilloscope have been erased. When a 1 kHz, 5V p-p square wave calibration pulse is connected to channel 1 ofthe scope the waveform observed on the screen is as shown in the upper trace of the figure. An unknown signal is connected to channel 2 (lower trace) ofthe scope. If the time/div and V/div on both channels are the same, the amplitude (pp) and period of the unknown signal are respectively.

asked May 20, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 17 views

A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 12 views

The measurement range of an ammeter can be increased by using a:

asked May 22, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 28 views

 A transformer has maximum efficiency at 3/4 full load. The ratio of its iron losses and full load copper loss is : -  a) 16/9 b) 4 / 3 c) 3/4 d) 9 /16

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 18 views

In the common–emitter transistor circuit, if the current gain is 100 and the collector current is 10 mA, the base current is: (1) 10 µA (2) 100 µA (3) 1 A (4) 10 A 

asked May 29, 2018 in Electronics Engineering by Shimroz123
1 answer 10 views

The current through a flashlight bulb is 40 mA and the total battery voltage is 4.5 V. The resistance of the bulb is approximately? A.112 ohms B.11.2 ohms C.1.2 ohms D.18 ohms

asked May 15, 2018 in Basic concepts by Shimroz123
1 answer 17 views

 Full load current of an Induction motor is 20 Ampere. The no-load current may be expected to be: A) 25 Ampere to 28 Ampere B) 15 Ampere to 18 Ampere C) 11 Ampere to 14 Ampere D) 6 Ampere to 10 Ampere

asked Jun 4, 2018 in Induction Machine by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,530 questions

7,130 answers

135 comments

3,090 users

...