Why do we use automation?

8 views
in Electrical Engineering by

1 Answer

0 votes
by

The series magnet of a single phase Energy meter consists of coil of thick wire of few turns.

Related questions

1 answer 17 views

The current coil of a single-phase energy meter is wound on (a) One limb of the laminated core (b) Both the limbs of the laminated core with same number of turns (c) Both the limbs of the laminated core with different number of turns (d) The centre of the limb on the laminated core

asked Apr 23, 2018 in Electrical Engineering by Shimroz123
1 answer 10 views

State the function and shape of following parts used in induction type energy meter: i) Series magnet ii) Shunt magnet iii) Al disc iv) Brake magnet

asked Sep 6, 2018 by Shimroz123
0 answers 31 views

A single phase energy meter has a constant of 1200 revolution/kWh. When a load of 200 W is connected, the disc rotates at 4.2 revolutions per min. If the load is on for 10 hours, the meter records an excess of   (a) 0.1 kWh (b) 0.2 kWh (c) 1.0 kWh (d) 2.0 kWh 

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
1 answer 9 views

In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by   (a) 90o (b) 0o (c) 45o (d) 60o

asked May 13, 2018 in Instrumentation and control by Shimroz123
1 answer 29 views

The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

asked Apr 25, 2018 in Instrumentation and control by Shimroz123
1 answer 11 views

One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is

asked Apr 23, 2018 in Electrical Engineering by Shimroz123
1 answer 16 views

The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be

asked Apr 23, 2018 in Electrical Engineering by Shimroz123
0 answers 53 views

The meter constant of a single phase 240 V induction watt hour meter is 400 revolutions per KWhr. The speed of the meter disc for a current of 10 A of 0.8 pf, lagging will be  (A) 12.8 rpm (B) 16.02 rpm (C) 18.2 rpm (D) 21.1 rpm 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

asked Apr 29, 2018 in Electrical Engineering by Shimroz123
1 answer 47 views

The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

asked Apr 25, 2018 in Instrumentation and control by Shimroz123
1 answer 11 views

 In a household single phase induction type wattmeter, the meter can be reversed by: - a) reversing the supply terminals b) reversing the load terminal c) opening the meter connection and reversing either the potential coil terminals or current coil terminals d) opening the meter and reversing the connection of both the potential coil terminals and current coil terminals

asked Apr 14, 2018 in Instrumentation and control by Shimroz123
2 answers 3 views

State the meaning of creeping error in 1 phase energy meter.

asked Sep 6, 2018 by Shimroz123
1 answer 9 views

In a flux meter, the controlling torque is _____.

asked May 29, 2018 in Electrical Engineering by Shimroz123
1 answer 16 views

The working of a meter is based on the use of a permanent magnet. In order to protect the meter functioning from stray magnetic fields

asked Mar 29, 2018 in Electrical engineering materials by Shimroz123
0 answers 41 views

If an energy meter disc makes 10 revolutions in 100 seconds when a load of 450W is connected to it, the meter constant in revolutions per kWh is  A) 1000 B) 500 C) 1600 D) 800

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
0 answers 61 views

An energy meter has a constant of 600 rev/kWh. If the meter makes 10 revolutions in 20 s, what is the load in kW?  (A) 0.75 kW (B) 1.5 kW (C) 3 kW (D) 6 kW 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 17 views

Single phase series motors are widely used in domestic appliances and operate at speeds (a) 500 to 1000 rpm (b) 1500 to 10,000 rpm (c) 15,000 to 20,000 rpm (d) 50 to 100 rpm

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
1 answer 21 views

A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

asked May 22, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 10 views

 In an energymeter which coil carries the current proportional to supply voltage _____. 

asked May 29, 2018 in Electrical Engineering by Shimroz123
0 answers 26 views

If 1 ampere current is flowing through a 100 mH coil, then energy stored in the coil is (a) 0.05 Joules (b) 0.5 Joules (c) 5.0 Joules (d) None of these

asked May 25, 2018 in Electrical Engineering by Shimroz123
1 answer 8 views

A two-phase generator is connected to two 90Ω load resistors. Each coil generates 120 V ac. The value of current flowing through the common neutral line will be: A. 1.33 A B. 1.88 A C. 2.66 A D. 1.77 A

asked Apr 12, 2018 in Electrical Engineering by Shimroz123
1 answer 14 views

 The main sources of Errors in Permanent Magnet moving Coil (PMMC) are due to : - a) weaking of the permanent magnet due to aging at temperature effects b) weaking of spring due to aging and temperature effects c) change of resistance of the moving coil with temperature d) all the above

asked Apr 14, 2018 in Instrumentation and control by Shimroz123
1 answer 30 views

For controlling the vibration of the disc of ac energy meter, damping torque is produced by

asked Apr 23, 2018 in Electrical Engineering by Shimroz123
1 answer 446 views

A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

asked Apr 28, 2018 in Electrical Engineering by Shimroz123
1 answer 41 views

The primary turns of a 444 V/222 V, 50 Hz single-phase transformer with a core cross-sectional area of 100 cm2, and a maximum flux density of 1.0 T is (A) 100 (B) 200 (C) 222 (D) 400

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 14 views

If the conductive loop on the rotor of a simple two -pole, single-phase generator rotates at the rate of 400 rps. The frequency of the induced output voltage will be: A. 40 Hz B. 100 Hz C. 400 Hz D. indeterminable

asked Apr 12, 2018 in Electrical Engineering by Shimroz123
1 answer 18 views

Comparing the total copper cross sections in terms of current-carrying capacity for a single-phase and a three-phase 120 V system with effective load resistance of 15Ω, will yield: A. single-phase 32 A; three-phase 16 A B. single-phase 16 A; three-phase 8 A C. single-phase 8 A; three-phase 4 A D. single-phase 16 A; three-phase 0 A

asked Apr 12, 2018 in Electrical Engineering by Shimroz123
0 answers 11 views

The no~load current of a single phase induction motor is around _____% of full load current.  (1) 10 (2) 20 (3) 40 (4) 80

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
1 answer 58 views

Starting torque can be obtained in the case of a single phase induction motor with identical main and auxiliary windings by connecting:  (1) A capacitor across the mains (2) A capacitor in series with the machine (3) A capacitor is series with the auxiliary winding (4) Equal value capacitors in series with the main and the auxiliary windings

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
0 answers 14 views

A single phase motor draws a current of 5 A from a 120 V, 60 Hz line. The power factor of the motor is 65%. Calculate the active power absorbed by the motor.  (A) 600 W (B) 390 W (C) 456 W (D) 650 W 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 13 views

if the rated voltage from the power lines is applied to the primary of a single-phase transformer which is operated on no-load, then

asked Apr 1, 2018 in Electrical Engineering by Shimroz123
1 answer 30 views

The Q factor of a coil at resonant frequency 1.5 MHz of an RLC series circuit is 150. The Bandwidth is : - a) 225 MHz b) 1.06 MHz c) 10 KHz d) 10 MHz

asked Apr 14, 2018 in Instrumentation and control by Shimroz123
0 answers 103 views

A balanced three phase Delta connected load consists of three resistances each of four ohm's connected to a 400 V 3 phase 50 Hz supply. Find 1) phase voltage, 2) phase current, 3) line current, 4) power consumed.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 10 views

A three phase 50 Hz line consists of three conductors each of diameter 21 mm, The spacing between the conductors all follows: A - B = 3m, B - C = 5m, C - A = 3.6m If the line operates at 132 k V, the reactive voltampere generatd by the line per km is?

asked Mar 27, 2018 in Power system by Shimroz123
0 answers 23 views

The constant of a given energy meter is 500 revolution/kWh. At the test 4.4 kW full load, meter completes 50 revolutions in 86 seconds. The percentage error of the meter is (a) –4.86% (b) 4.86% (c) 2.0% (d) 3.0%

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 19 views

A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

asked Apr 28, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 12 views

Two voltmeters of same range, one moving iron type and other permanent magnet moving coil type, are connected in parallel for measuring a.c. supply voltage. If the reading of MI type is 300V, the reading of PMMC type will be (a) zero (b) higher-than M.I. type (c) lower than M.I. type (d) same

asked May 25, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 11 views

Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be

asked Apr 23, 2018 in Electrical Engineering by Shimroz123
1 answer 11 views

Name the material used for :- (i) Moving coil (ii) Permanent magnet in PMMC instrument.

asked Sep 6, 2018 by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,450 questions

7,047 answers

132 comments

3,084 users

...