A series RLC circuit has a resonant frequency of 1 KHz and a quality factor Q = 100. If each of the R,L and C is doubled from its original value, the new Q of the circuit is: 

(1) 25 (2) 50 (3) 100 (4) 200

Your answer

Thanks for your contribution. Feel free to answer this question. Please avoid short answer. Your answer is most welcome. Be genuine.

Upload image or document:

Your name to display (optional):
Privacy: Your email address will only be used for sending these notifications.
Anti-spam verification:
Are you a robot ? (Y = Yes / N = No)
To avoid this verification in future, please log in or register.

1 Answer

0 votes
answered by

A series RLC circuit has a resonant frequency of 1 KHz and a quality factor Q = 100. If each of the R,L and C is doubled from its original value, the new Q of the circuit is: 200.