51 views
in Electrical Engineering by
If the stator winding of a three-phase induction motor is delta connected, the rotor winding 

 (a) should be delta connected (b) should be star connected (c) should not be delta connected (d) may be delta or star connected 

Related questions

1 answer 20 views

A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: (1) Slip frequency (2) Supply frequency (3) Frequency corresponding to rotor speed (4) Zero

asked May 22, 2018 in Induction Machine by Shimroz123
0 answers 19 views

The stator of a 3 phase, 10 pole induction motor possesses 120 slots. If a lap winding is used, calculate the coil pitch, if the coil width extends from slot 1 to slot 11.  (A) 72.12% (B) 83.30% (C) 12% (D) 42% 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 39 views

The rotor winding of a three phase wound rotor induction motor is equipped with a three phase diode rectifier connected to the slip rings and rectifier output is connected with chopper drive. Compared to conventional rotor resistance control scheme, the chopper controlled method  A) Enhances the motor rating B) Maintains the motor rating as such C) Derates the motor D) None of the above 

asked Apr 9, 2018 in Electrical Machine by Zeeshan
1 answer 322 views

in a three-phase induction motor, the rotor field runs at the following speed with respect to the stator structure: 

asked May 22, 2018 in Induction Machine by Shimroz123
0 answers 19 views

The power input to the rotor of a 400V, 50 Hz 6 pole three phase induction motor is 20kW. The slip is 3%. The frequency of rotor currents is: (A) 1 Hz (B) 1.5 Hz (C) 2 Hz (D) 1 2 Hz

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
1 answer 18 views

Three equal impedances are first connected in delta across a 3 -phase balanced supply. If the same impedances are connected in star across the same supply then,

asked Apr 23, 2018 in Electrical Engineering by Zeeshan
0 answers 20 views

If the supply frequency of a 3-phase induction motor is ‘f’, then frequency of rotor emf at motor slip ‘s’ will be   (a) sf (b) (1 – s)f (c) f/s (d) None of these 

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
0 answers 24 views

The stator mmf and rotor mmf of a 3-phase induction motor (A) are equal (B) rotate with slip speed (C) are opposite but rotate with synchronous speed (D) rotate with the same rotor speed 

asked Jun 4, 2018 in Induction Machine by Shimroz123
1 answer 23 views

In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in the same direction (C) the flux increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 15 views

A 3-phase induction motor under locked rotor condition and with stator supply, induces (A) small voltage at slip frequency (B) large voltage at rotor frequency (C) zero voltage at zero frequency (D) large voltage at slip frequency

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 12 views

A three phase induction motor is driving full -load torque which is independent of speed. If the line voltage drops to 90% of the rated value, % increase in motor copper losses  (a) 23% (b) -18% (c) 123% (d) None of these

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
0 answers 19 views

A delta connected 400 V, 50 Hz, 3-phase induction motor when started direct-on-line takes a starting current of 30 A. When the motor is started through a star-delta starts, the starting current will be (1) 3A (2) 10 A (3) 15 A (4) 30 A 

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 21 views

A three-phase, three-stack, variable reluctance step motor has 20 poles on each rotor and stator stack. The step angle of this step motor is  (A) 3o (B) 6o (C) 9o (D) 18o

asked May 17, 2018 in Transformer by Shimroz123
1 answer 29 views

An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is (A) 5.06 kW (B) 0.3 kW (C) 100 kW (D) 83.33 kW

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 18 views

If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is:

asked May 22, 2018 in Induction Machine by Shimroz123
0 answers 82 views

Three single phase transformers each with 10 kVA rating are connected in a closed delta arrangement. If one transformer is taken out, the output capacity of the system will be (a) 20 kVA (b) 8.66 kVA (c) 17.32 kVA (d) 10 kVA

asked May 25, 2018 in Single phase transformer by Shimroz123
1 answer 80 views

The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

asked May 17, 2018 in Electrical Machine by Shimroz123
2 answers 26 views

Stator Voltage Control of three phase induction motor

asked Aug 9, 2017 in Electrical Machine by Zeeshan
1 answer 13 views

A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used:

asked May 22, 2018 in Induction Machine by Shimroz123
0 answers 18 views

Three single phase transformers are connected in delta-delta to step down a line voltage of 138 kV to 4160 V to supply power to a production plant. The plant draws 21 MW at a lagging power factor of 86 %. Calculate the apparent power furnished by the HV line.  (A) 24.4 MVA (B) 48.8 MVA (C) 12.2 MVA (D) 6.1 MVA 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 41 views

A 0.5 Hp, 6 pole wound rotor induction motor is excited by a 3 phase 60 Hz source. Calculate the frequency of the rotor current at standstill.  (A) 50 Hz (B) 30 Hz (C) 60 Hz (D) 120 Hz 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 15 views

A three-phase cage induction motor is started by direct-on-line (DOL) switching at the rated voltage. If the starting current drawn is 6 times the full load current, and the full load slip is 4%, then ratio of the starting developed torque to the full load torque is approximately equal to (A) 0.24 (B) 1.44 (C) 2.40 (D) 6.00

asked May 17, 2018 in Induction Machine by Shimroz123
1 answer 21 views

Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be

asked Apr 29, 2018 in Electrical Machine by Shimroz123
1 answer 21 views

A centre zero ammeters connected in the rotor circuit of a 6-pole 50 Hz induction motor makes 30 oscillations in one minute. The rotor speed is

asked Apr 1, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

Types of three phase induction motor rotor

asked Aug 9, 2017 in Electrical Machine by Zeeshan
1 answer 28 views

A three-phase transformer, connected in star-delta, is composed of three single-phase transformers, each rated 127/ 13.2 kV. The line-to-line voltage ratio for the three-phase transformer is: A) 220 / 13.2 kV B) 127 / 13.2 kV C) 127 / 220 kV D) 220 / 220 kV

asked Jun 4, 2018 in Three phase transformers by Shimroz123
0 answers 22 views

Calculate the approximate locked rotor current of a 3 phase induction motor having a rating of 500 Hp, 2300 V.  (A) 130 A (B) 39 A (C) 390 A (D) 780 A 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 19 views

At slip equal to infinity, the torque of a three phase induction motor is :-  a) zero b) very small c) high d) very high

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
0 answers 11 views

A 3-phase, 50 Hz, 500 V induction motor develops 20 hp at slip of 5%. Mechanical losses are 1 hp, and stator loss is 1 kW. The efficiency will be   (a) 95.3% (b) 90.5% (c) 91.3% (d) 85.3% 

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
0 answers 103 views

A balanced three phase Delta connected load consists of three resistances each of four ohm's connected to a 400 V 3 phase 50 Hz supply. Find 1) phase voltage, 2) phase current, 3) line current, 4) power consumed.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
0 answers 38 views

A balanced Delta connected load supplied with 440 V 50 Hz three phase AC supply has R=10 Ohm and L=0.6 mH in is each arm. Calculate line and phase current, active power.

asked Aug 12, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 11 views

The rotor frequency for a 3-phase 6-pole, 1000 r.p.m. induction motor with a slip of 0.04 is (a) 2 Hz (b) 4 Hz (c) 6 Hz (d) 8 Hz  

asked May 25, 2018 in Induction Machine by Shimroz123
1 answer 27 views

The rotor power output of a 3 -phase induction motor is 15 kW and the corresponding slip is 4%. The rotor copper losses will be: (A) 600 W (B) 625 W (C) 650 W (D) 700 W

asked Apr 11, 2018 in Computer Engineering by Shimroz123
1 answer 123 views

An 1.8° step, 4 -phase stepper motor has 40 teeth on 8 poles of the stator. The number of rotor teeth for their rotor will be: (A) 40 (B) 50 (C) 100 (D) 80

asked Apr 11, 2018 in Computer Engineering by Shimroz123
1 answer 34 views

A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m

asked Apr 11, 2018 in Electrical Engineering by Shimroz123
1 answer 14 views

An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be  A) 40 Nm B) 60 Nm C) 90 Nm D) 120 Nm

asked May 17, 2018 in Induction Machine by Shimroz123
1 answer 20 views

In a capacitor start single-phase induction motor, the capacitor is connected in:  (A) series with the main winding (B) series with the auxiliary winding (C) series with both the windings (D) parallel with the auxiliary winding .

asked Apr 9, 2018 in Electrical Engineering by Shimroz123
1 answer 62 views

What type of excitation is given to the rotor winding of a synchronous motor?  (A) DC supply at 100 -250 V (B) AC supply at 400 V (C) Revolving field (D) Induction from stator currents 

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
0 answers 28 views

Three resistances of 3 Ω each are connected in delta. The value of the resistances in the equivalent star is : (A) 27 (B) 9 (C) 1.5 (D) 1 Ω

asked Mar 31, 2018 in Electrical Engineering by Shimroz123
1 answer 32 views

A 3-phase, 4-pole, 50Hz induction motor runs at a speed of 1440 rpm. The rotating field produced by the rotor rotates at a speed of ________ rpm with respect to stator field. (A) 1500 (B) 0 (C) 1440 (D) 60

asked Apr 28, 2018 in Electrical Machine by Shimroz123
1 answer 38 views

The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above

asked May 1, 2018 in Electrical Machine by Shimroz123
1 answer 16 views

In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve (A) low starting torque (B) quick acceleration (C) high efficiency (D) reduced size

asked May 17, 2018 in Induction Machine by Shimroz123
0 answers 28 views

Draw the Delta connected three phase system showing all the voltages and currents. Write the power equation.

asked Aug 11, 2018 in Basic electrical and electronics engineering by Quiz
1 answer 21 views

Two single-phase 150 kVA, 7200/ 600 volt transformers are connected in open-delta. The maximum three-phase load that they can carry is: A) 300 kVA B) 75 kVA C) 259 kVA D) 249 kVA

asked Jun 4, 2018 in Single phase transformer by Shimroz123
1 answer 24 views

A 6 pole 3-phase wound-rotor induction machine is driven by another machine at 1800 rpm. The rotor of the induction machine is connected to a 50Hz system. If the mechanical rotation of the rotor is in the same direction as the rotor winding flux rotation, then frequency of the stator voltage will be

asked Apr 1, 2018 in Electrical Engineering by Shimroz123
1 answer 24 views

A permanent magnet stepper motor with 8 poles in stator and 6 poles in rotor will have a step angle of (a) 7.5° (b) 15° (c) 30° (d) 60°

asked Apr 25, 2018 in Electrical Engineering by Shimroz123
1 answer 29 views

how can we reverse the direction of rotation of three phase induction motor ?

asked Oct 4, 2017 in Electrical Engineering by Quiz

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,450 questions

7,047 answers

132 comments

3,085 users

...