9 views
in Instrumentation and control by
 Maxwell's inductance - capacitance bridge is used for measurement of Inductance of: - 

a) Low Q coils b) Medium Q coils c) High Q coils d) Low and medium Q coils

Your answer

Thanks for your contribution. Feel free to answer this question. Please avoid short answer. Your answer is most welcome. Be genuine.

Upload image or document:

Your name to display (optional):
Privacy: Your email address will only be used for sending these notifications.
Anti-spam verification:
Are you a robot ? (Y = Yes / N = No)
To avoid this verification in future, please log in or register.

1 Answer

0 votes
by

 Maxwell's inductance - capacitance bridge is used for measurement of Inductance of: - Medium Q coils

Related questions

0 answers 22 views

For measurement of low resistance, the bridge used is (a) Wheatstone (b) Kelvin (c) Maxwell (d) Anderson

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 11 views

Weins bridge is used for measurement of frequency in the applied voltage waveform is measurement of frequency in the applied voltage waveform is   (A)sinusoidal (B) square (C) rectangular (D) triangular

asked May 17, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 12 views

Maxwell's bridge is used to measure (A) Inductance (B) Frequency (C) Capacitance (D) Resistance

asked May 13, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 27 views

The bridge method commonly used for finding mutual inductance is (A) Heaviside Campbell bridge (B) Schering bridge (C) De Sauty bridge (D) Wien bridge

asked Apr 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 79 views

Wagner's earth devices are used in AC bridge circuits for (a) Eliminating the effect of earth capacitances (b) Eliminating the effect of intercomponent capacitances (c) Eliminating the effect of stray electrostatic fields (d) Shielding the bridge elements

asked May 13, 2018 in Instrumentation and control by Shimroz123
1 answer 10 views

 A Wheatstone bridge cannot be used for precision measurements because errors are introduced into on account of: - a) Resistance of the connecting lead b) Thermoelectric EMFs c) Contact resistance d) all the above

asked Apr 14, 2018 in Instrumentation and control by Shimroz123
0 answers 7 views

Hay bridge is suitable for measuring following type of inductance (a) having Q greater than 10. (b) having Q less than 10. (c) having any value of Q. (d) having phase angle of reactance very large. 

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 15 views

The bridge most suited for accurate measurement of relative permittivity of dielectric materials is (A) Carey Foster Bridge (B) Anderson’s bridge (C) Heaviside Bridge modified by Campbell. (D) Schering Bridge.

asked Apr 28, 2018 in Control System by Shimroz123
0 answers 22 views

Which parameter or quantity may be measured by use of Maxwell's Bridge ? (A) Resistance (B) Capacitance (C) Inductance (D) Frequency

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
1 answer 3 views

Describe with working of LCR meter for measurement of inductance. 

asked Sep 6, 2018 by Shimroz123
1 answer 14 views

The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

asked Apr 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 20 views

A 800 kV transmission line is having per phase line inductance of 1.1 mH/km and per phase line capacitance of 11.68 nF/km. Ignoring the length of the line, its ideal power transfer capability in MW is (A) 1204 MW (B) 1504 MW (C) 2085 MW (D) 2606 MW

asked May 25, 2018 in Power system by Shimroz123
0 answers 18 views

A parallel combination of capacitance C and resistance R is connected in series with inductance L and small resistance r. Under what condition will the circuit be non-reactive?  (A) C=LR (B) C=LR2 (C) C=L/R2 (D) C=L/R

asked Apr 5, 2018 in Electrical Engineering by Shimroz123
1 answer 8 views

Clamp on ammeter is used for measurement of:

asked May 22, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 56 views
0 answers 13 views

The LVDT is used for the measurement of (a) voltage (b) force (c) pressure (d) displacement

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
1 answer 8 views

State the effects of errors in dynamometer type wattmeter due to i) pc- inductance ii) pc- capacitance iii) mutual inductance iv) Connection.

asked Sep 6, 2018 by Shimroz123
0 answers 59 views

A cable has inductance of 0.22 mH per kilometer and capacitance of 0.202 µF per kilometer. The surge impedance of the cable is (a) 50 Ω (b) 42 Ω (c) 33 Ω (d) 28 Ω

asked May 26, 2018 in Electric Power Transmission by Shimroz123
1 answer 22 views

With the help of which bridge are the capacitance and dielectric loss of a capacitor generally measured ?

asked Apr 23, 2018 in Electrical Engineering by Shimroz123
1 answer 21 views

 In measurement system, which of the following static characteristics is desirable ? a) accuracy b) sensitivity c) reproducibility d) all the above

asked Apr 14, 2018 in Instrumentation and control by Shimroz123
1 answer 23 views

The Maxwell bridge is used for measuring (a) Capacitance (b) Dielectric loss (c) Inductance (d) Phase angle 

asked May 26, 2018 in Electrical Measurements and Instrumentation by Shimroz123
1 answer 7 views

With neat diagram, explain working of capacitance level measurement.

asked Sep 9, 2018 by Shimroz123
1 answer 23 views

Which of the following transducers can be used for non-contact temperature measurement? A) Resistance temperature detector B) Thermistor C) Sensistor D) Pyrometer 

asked Jun 17, 2018 in Electronics Engineering by Shimroz123
1 answer 13 views

Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

asked Jun 17, 2018 in Electrical Measurements and Instrumentation by Shimroz123
0 answers 12 views

Hall effect transducers are generally used for the measurement of (A) Magnetic field (B) Current (C) Electric field (D) Pressure

asked Apr 14, 2018 in Electrical Engineering by Shimroz123
1 answer 28 views

Which method can be used for absolute measurement of resistance? A. Ohm's law method B. Wheatstone bridge method C. Both A & B D. None of these. 

asked Apr 12, 2018 in Electrical Engineering by Shimroz123
0 answers 27 views

A CRO cannot be used for direct measurement of   (a) Voltage (b) Current (c) Frequency (d) Power

asked Apr 10, 2018 in Electrical Engineering by Shimroz123
1 answer 10 views

How strain gauge is used for pressure measurement, explain?

asked Sep 12, 2018 by Shimroz123
1 answer 8 views

What is capsule? How it is used for pressure measurement?

asked Sep 9, 2018 by Shimroz123
1 answer 71 views

 The term absolute Pressure is used for a pressure measured relative to: - a) vacuum pressure b) some fixed pressure c) atmospheric d) all the above

asked Apr 14, 2018 in Instrumentation and control by Shimroz123
1 answer 23 views

In series resonant circuit, increasing inductance to its twice value and reducing capacitance to its half value?  

asked Mar 25, 2018 in Electrical Engineering by Shimroz123
1 answer 41 views
1 answer 13 views

Describe the instrumentation system used for temperature measurement using thermistor.

asked Sep 13, 2018 by Shimroz123
1 answer 25 views

Thermocouple instruments can be used for a frequency range upto   (a) 100Hz (b) 5000 Hz (c) 1 MHz (d) 50 MHz and above 

asked May 13, 2018 in Instrumentation and control by Shimroz123
1 answer 11 views

 Dummy strain gauges are used for : -  a) compensation of temperature changes b) increasing the sensitivity of bridge in which they are included c) compensating for different expansion d) calibration of strain gauge

asked Apr 10, 2018 in Instrumentation and control by Shimroz123
1 answer 15 views

 Capacitive transducers are normally used for : -  a) static measurements b) dynamic measurements c) both static and dynamic measurements d) transient measurements

asked Apr 10, 2018 in Instrumentation and control by Shimroz123

Welcome to electronics2electrical.com here you can ask questions related to electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc.
Be respectful to all the members. Do not copy and paste the answers from other websites which have copyright content. While asking question give full details about it.

Categories

Most popular tags

power motor dc circuit transformer voltage current used system phase resistance factor synchronous load ac energy induction electric generator series frequency between speed capacitor use electrical meter line difference control type mosfet transmission magnetic plant high single instrument bjt unit source advantages function diode and machine winding field define torque parallel amplifier supply shunt thyristor motors electricity arduino maximum time relay armature problem value on transformers types coil diagram state flow ratio material three formula starting direction theorem method emf operating efficiency digital wave microprocessor test instruments inductance loss measure operation connected signal low applications effect single-phase network temperature working constant losses different law wattmeter measuring compare controlled breaker drive device logic rc full switch flux wire resistivity disadvantages free of materials machines angle force converter conductor transistor gain open protection scr core measurement number bridge principle generators reactance circuits negative the friction iron loop short pole battery conservation steam resistors hysteresis computer using analog lines secondary station gate a rectifier inverter linear induced relays nuclear capacitance basic characteristics design direct work rotor electronics ammeter forces diesel damping rlc connection factors capacitors minimum insulation moving regulation running self systems air fault range main stability quality starter igbt eddy alternator ideal rl average 3-phase plants arc thermal error fuzzy biasing dielectric pressure balanced superposition errors copper rotation feedback impedance measured electronic electrons charge inductive transfer explain start off back curve over solar is three-phase tariff locomotive peak bias zener engineering commutator surge conductors rating universal potentiometer density permanent mechanical transducer capacity memory adc excitation two fuse pure harmonics application semiconductor inductor internal pmmc reaction welding resonance traction permeability breakers rms designed electromagnetic si generation brushes switching capacitive shaded rate 1 distribution resistor methods delta star oscillator reluctance simplification algebra 8085 boolean weston dynamometer insulating strength installation definition fuel heating earth units

8,530 questions

7,130 answers

135 comments

3,090 users

...