A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m
in Electrical Engineering by

1 Answer

0 like 0 dislike

A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is: 75 r.p.m

by

Related questions

Ask Price : 09175036778

Buy Obstacle Avoidance Robot (Final year project) . Call or whatsapp now (India only) 09175036778

Intrested ?: Intrested

9,100 questions

7,861 answers

142 comments

3,165 users